SITRANS P measuring instruments for pressure

Transmitters for gage pressure for the paper industry

SITRANS P300 with PMC connection

Technical specifications

 

 

SITRANS P300 for gage pressure with PMC connection for the paper industry

 

 

 

 

 

 

 

HART

 

 

 

PROFIBUS PA

 

 

 

 

 

 

 

 

 

 

 

 

2

 

Input

 

 

 

 

 

 

 

 

Measured variable

Gage pressure (flush-mounted)

 

 

 

 

 

 

Spans (infinitely adjustable) or

Span

 

Max. perm. test pres-

 

Nominal measuring

 

Max. perm. test pres-

 

 

 

 

 

 

 

nominal measuring range and

 

 

sure

 

range

 

sure

 

 

max. permissible test pressure

0.01 ... 1 bar g

 

6 bar g

 

1 bar g

 

6 bar g

 

 

 

 

 

 

 

 

 

(0.15 ... 14.5 psi g)

 

(87 psi g)

 

(14.5 psi g)

 

(87 psi g)

 

 

 

0.04 ... 4 bar g

 

10 bar g

 

4 bar g

 

10 bar g

 

 

 

(0.58 ... 58 psi g)

 

(145 psi g)

 

(58 psi g)

 

(145 psi g)

 

 

 

0.16 ... 16 bar g

 

32 bar g

 

16 bar g

 

32 bar g

 

 

 

(2.3 ... 232 psi g)

 

(464 psi g)

 

(232 psi g)

 

(464 psi g)

 

 

 

Depending on the process connection, the span

 

Depending on the process connection, the nomi-

 

 

 

may differ from these values

 

nal measuring range may differ from these values

 

 

Lower measuring limit

 

 

 

 

 

 

 

 

 

• Measuring cell with silicone oil

100 mbar a (1.45 psi a)

 

 

 

 

 

 

 

 

Upper measuring limit

 

 

 

 

 

 

 

 

 

• Measuring cell with silicone oil

100% of max. span

 

 

 

100% of the max. nominal measuring range

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output

 

 

 

Output signal

4 ... 20 mA

 

Digital PROFIBUS PA signal

Physical bus

-

 

IEC 61158-2

With polarity reversal protection

No

 

Yes

Electrical damping T63 (step width 0.1 s)

Set to 0.1 s (0 ... 100 s)

 

 

 

 

 

 

 

 

Accuracy

To EN 60770-1

 

 

Reference conditions

Increasing characteristic, start-of-scale value 0 bar, stainless steel seal diaphragm, measuring cell

(All error data refer always refer to the set

with silicone oil, room temperature 25 °C (77 °F), span ratio (r = max. span/set span)

span)

 

 

 

Measurement deviation with cut-off point set-

 

 

 

ting, including hysteresis and repeatability.

 

 

 

Linear characteristic curve

 

 

0,075%

 

 

• r 10

(0.0029 r + 0.071)%

 

 

• 10 < r 30

(0.0045 r + 0.071)%

 

 

• 30 < r 100

(0.005 r + 0.05)%

 

 

Settling time T63 without electrical damping

Approx. 0.2 s

 

 

 

 

Long-term drift at ±30 °C (±54 °F)

(0.25 r)%/5 years

 

0.25%/5 years

 

Influence of ambient temperature

 

 

 

 

 

 

• at -10 ... +60 °C (14 ... 140 °F)

(0.1 r + 0.2)%

 

0,3%

 

• at -40 ... -10 °C and +60 ... +85 °C

(0.1 r + 0.15)%/10 K

 

0.25%/10 K

(-40 ... 14 °F and 140 ... 185 °F)

 

 

 

Influence of the medium temperature (only

 

 

 

with front-flush diaphragm)

 

 

 

• Temperature difference between medium

3 mbar/10 K (0.04 psi/10 K)

 

 

temperature and ambient temperature

 

 

 

 

 

 

 

Rated operating conditions

 

 

 

Installation conditions

 

 

 

Ambient temperature

Observe the temperature class in areas subject to explosion hazard.

• Measuring cell with silicone oil

-40 ... +85 °C (-40 ... +185 °F)

 

 

• Digital display

-30 ... +85 °C (-22 ... +185 °F)

 

 

• Storage temperature

-50 ... +85 °C (-58 ... +185 °F)

 

 

Climatic class

 

 

 

Condensation

Permissible

 

 

Degree of protection to EN 60529

IP65, IP68, NEMA X, enclosure cleaning, resistant to lyes, steam to 150° C (302 °F)

Electromagnetic compatibility

 

 

 

• Emitted interference and interfer. immunity

To EN 61326 and NAMUR NE 21

 

 