Siemens P technical specifications 165

Models: P

1 234
Download 234 pages 4.66 Kb
Page 165
Image 165

© Siemens AG 2008

SITRANS P measuring instruments for pressure

Selection and Ordering data

 

Order No. Ord.code

Diaphragm seal

 

D)

7

M F 4 9 1

0 -

 

Directly fitted to a pressure transmitter

 

 

77777

 

 

 

777

SITRANS P for pressure 7MF403 7 and

 

 

 

 

 

 

 

 

 

7MF4237 together with Order code "V01" (vac-

 

 

 

 

 

 

 

 

 

uum-proof design) and 7MF80271); must be

 

 

 

 

 

 

 

 

 

ordered separately

 

 

 

 

 

 

 

 

 

 

Process connection

 

 

 

 

 

 

 

 

 

 

• Vertical (pressure transmitter upright)

 

0

 

 

 

 

 

 

 

• Horizontal

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Nominal diameter and nominal pressure

 

 

 

 

 

 

 

 

 

• DN 50

PN 40

 

 

A

 

 

 

 

PN 100

 

 

B

 

 

 

• DN 80

PN 40

 

 

D

 

 

 

 

PN 100

 

 

E

 

 

 

• DN 100

PN 16

 

 

G

 

 

 

 

PN 40

 

 

 

 

 

 

 

 

 

H

 

 

 

 

 

• 2 inch

Class 150

 

 

L

 

 

 

 

 

 

Class 300

 

 

M

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Class 600

 

 

N

 

 

 

 

 

 

Class 1500

 

 

P

 

 

 

 

 

• 3 inch

Class 150

 

 

Q

 

 

 

 

 

 

Class 300

 

 

R

 

 

 

 

 

 

Class 600

 

 

S

 

 

 

 

 

• 4 inch

Class 150

 

 

T

 

 

 

 

 

 

Class 300

 

 

U

 

 

 

 

 

 

Class 400

 

 

V

 

 

 

 

 

Smooth sealing face to DIN 1092-01, form B1 or

 

 

 

 

 

 

 

 

 

B2, or to ASME B16.5 125 ... 250 AA or RFSF

 

 

 

 

 

 

 

 

 

Other version

 

 

 

 

 

 

 

 

 

 

 

 

Z

 

 

 

 

J 1 Y

Add Order code and plain text:

 

 

 

 

 

 

 

 

 

Nominal diameter: ...; Nominal pressure: ...

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wetted parts materials

 

 

 

 

 

 

 

 

 

• Stainless steel 316L

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

- without foil

 

 

 

 

A

 

 

 

 

- with PTFE coating

 

 

 

 

E

0

 

 

 

- with ECTFE coating2)

 

 

 

F

 

 

 

 

- with PFA coating

 

 

 

 

D

 

 

 

 

• Monel 400, mat. No. 2.4360

 

 

 

G

 

 

 

 

• Hastelloy C276, mat. No. 2.4819

 

 

 

J

 

 

 

 

• Hastelloy C4, mat. No. 2.4610

 

 

 

U

 

 

 

 

• Tantalum

 

 

 

 

K

 

 

 

 

Other version

 

 

 

 

Z

 

 

 

 

 

 

 

 

K 1 Y

Add Order code and plain text:

 

 

 

 

 

 

 

 

 

Wetted parts materials: ...

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Tube length

 

 

 

 

 

 

 

 

 

 

• Without tube

 

 

 

0

 

 

 

 

• 50 mm

• (1.97 inch)

 

 

1

 

 

 

 

• 100 mm

• (3.94 inch)

 

 

2

 

 

 

 

• 150 mm

• (5.90 inch)

 

 

3

 

 

 

 

• 200 mm

• (7.87 inch)

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

Other version:

 

 

 

9

 

 

 

 

 

 

 

 

L 1 Y

Add Order code and plain text:

 

 

 

 

 

 

 

 

 

Tube length: ...

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Diaphragm seals of flange design

 

 

For gage and absolute pressure,

 

 

 

 

directly fitted on transmitter

 

 

 

 

 

 

 

 

 

 

Selection and Ordering data

 

Order No. Ord.code

 

 

 

 

 

 

 

 

 

 

 

 

Diaphragm seal

D)

7 M F 4

9 1 0 -

 

 

 

 

 

 

Directly fitted to a pressure transmitter

 

 

77777

 

 

777

 

 

 

 

 

SITRANS P for pressure 7MF4037 and

 

 

 

 

 

 

 

 

 

 

 

7MF4237 together with Order code "V01" (vac-

 

 

 

 

 

 

 

 

 

 

 

uum-proof design) and 7MF80271); must be

 

 

 

 

 

 

 

 

2

 

 

ordered separately

 

 

 

 

 

 

 

 

 

Filling liquid

 

 

 

 

 

 

 

 

 

 

 

• Silicone oil M5

 

 

 

1

 

 

 

 

 

 

 

• Silicone oil M50

 

 

 

2

 

 

 

 

 

 

 

High-temperature oil

 

 

 

3

 

 

 

 

 

 

 

• Halocarbon oil (for measuring O2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

• Glycerin/water3)

 

 

 

6

 

 

 

 

 

 

 

• Food oil (FDA listed)

 

 

 

7

 

 

 

 

 

 

 

Other version

 

 

 

9

 

M 1 Y

 

 

 

Add Order code and plain text:

 

 

 

 

 

 

 

 

 

 

 

Filling liquid: ...

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1)With 7MF8027 and the measuring cells Q, S, T and U also order the vac- uum-tight version.

2)For vacuum on request.

3)Not suitable for use in low-pressure range.

D) Subject to export regulations AL: N, ECCN: EAR99H.

Selection and Ordering data

Order code

Further designs

 

Please add "-Z" to Order No. and specify Order code.

 

 

 

Spark arrestor

A01

With spark arrestor for mounting on zone 0 (including

 

 

documentation) for transmitters for pressure and abso-

 

lute pressure

 

 

 

Quality inspection certificate (Factory calibration) to

C11

IEC 60770-2

 

to IEC 60770-2

 

 

 

 

Acceptance test certificate

C12

to EN 10204, section 3.1

 

 

 

 

Vacuum-proof design

V01

for use in low-pressure range for transmitters for

 

 

pressure

 

 

 

Calculation of span of associated pressure

Y05

transmitter

 

Enclose filled-in questionnaire with order

Siemens FI 01 · 2009

2/165

Page 165
Image 165
Siemens P technical specifications 165