© Siemens AG 2008

SITRANS P measuring instruments for pressure

Transmitters for gage, absolute and differential pressure

Z series for gage pressure

 

 

 

 

 

Design

 

 

 

Technical specifications

 

0.2 kg (0.44 lb)

 

 

 

 

 

 

Weight

 

 

SITRANS P pressure transmitter, Z series for gage pressure

 

 

 

 

 

Wetted parts materials

 

 

 

 

 

 

 

 

 

 

 

 

Mode of operation

 

 

 

 

 

 

 

 

 

• Measuring cell

Al2O3 - 96%

 

 

Measuring principle

Thin-film strain gage

 

 

 

 

2

 

 

 

 

 

• Process connection

Brass, mat. No. 2.0402

 

Input

 

 

 

 

 

 

• Gasket

Viton

 

Measured variable

Realtive pressure

 

 

 

 

 

 

Process connection

Male thread G½B

 

 

Measured range

0 to 16 bar g (0 to 232 psi g) or

 

 

 

 

 

 

 

female thread G1/ B

 

 

 

0 to 25 bar g (0 to 363 psi g)

 

 

 

8

 

 

 

 

 

 

Power supply

 

 

 

 

 

 

 

 

 

 

 

 

Output

 

 

 

Terminal voltage on pressure trans-

 

 

 

 

 

 

 

 

 

 

 

 

Current output signal

4 ... 20 mA

 

 

mitter

 

 

 

 

 

 

 

 

• For current output

10 to 36 V DC

 

 

Measuring accuracy

To EN 60770-1

 

 

 

 

Error in measurement (at 25 °C

0.5% of full-scale value-typical

 

 

 

 

 

 

 

 

 

Certificate and approvals

 

 

 

 

(77 °F), including conformity error,

 

 

 

Classification according to pressure

For gases of fluid group 1 and

 

 

hysteresis and repeatability)

 

 

 

 

 

 

 

 

equipment directive

liquids of fluid 1; complies with

 

 

 

 

 

 

 

 

Response time T99

< 0.1 s

 

 

(DRGL 97/23/EC)

requirements of article 3, para-

 

 

Long-term drift

 

 

 

 

graph 3 (sound engineering prac-

 

 

 

 

 

 

tice)

 

 

 

 

 

 

 

 

 

• Start of scale

0.3% of full-scale value/year - typ-

 

 

 

 

 

 

 

 

ical

 

 

 

 

 

 

 

• Measured span

0.3% of full-scale value/year - typ-

 

 

 

 

 

 

Dimensional drawings

 

 

 

 

 

ical

 

 

 

Influence of ambient temperature

• Start of scale

0.3%/10 K (0.3%/10 K) of full-

 

scale value - typical

• Measured span

0.3%/10 K (0.3%/10 K) of full-

 

scale value - typical

 

 

 

Rated conditions

 

 

Medium conditions

 

 

• Process temperature

-30

... +120 °C (-22 ... +248 °F)

Degree of protection to EN 60529

IP65

Ambient conditions

 

 

• Ambient temperature

-25

... 85 °C (-13 ... +185 °F)

• Storage temperature

-50

... 100 °C (-58 ... +212 °F)

 

 

 



 

 



 

B

 GLDP

 

G/

*%

 

8

 

 

 

6:

0[

SITRANS P pressure transmitters, Z series (7MF1562-...), dimensions in

mm (inch)

Schematics

Signal

1+

I0

+

 

 

 

U

 

2-

 

B

 

RL

 

 

 

 

 

I0 Output current

UB Power supply

RL Load

Connections:

1(+UB)

2 (-UB)

 

 

 

 

 

SITRANS P pressure transmitters, Z series (7MF1562-...), connection dia-

 

 

 

 

 

gram

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Selection and Ordering data

 

 

 

Order No.

Order code

 

 

 

 

SITRANS P pressure transmitters, Z series for pressure

D)

7 M F 1 5 6 2 -

7

77

0 0

 

777

 

 

2-wire system, characteristic rising

 

 

 

 

 

 

 

 

 

 

 

 

Measured range

Max. working pressure

 

 

 

 

 

 

 

 

 

 

0 ... 16 bar g

(0 ... 232 psi g)

32 bar g

(464 psi g)

 

 

3

C

B

 

 

 

 

 

0 ... 25 bar g

(0 ... 363 psi g)

64 bar g

(928 psi g)

 

 

3

C

D

 

 

 

 

 

Other version for measuring range 1 bar g (14.5 psi g), add Order code and plain text:

 

 

9

A

A

 

 

H 1 Y

 

 

Measuring range: ... to ... bar g (psi g)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D) Subject to export regulations AL: N, ECCN: EAR99H.

Siemens FI 01 · 2009

2/5

Page 5
Image 5