© Siemens AG 2008

SITRANS P measuring instruments for pressure

Transmitters for gage, absolute and differential pressure, flow and level

DS III series for absolute pressure (from gage pressure series)

Selection and Ordering data

Order No.

SITRANS P pressure transmitters for absolute F)

7 M F 4 2 3 3 -

pressure, from the pressure series DS III HART

77777 -

7777

 

 

Measuring cell filling

Measuring cell

 

 

 

cleaning

 

 

Silicone oil

Standard

1

 

Inert liquid1)

Grease-free

3

 

Span

 

 

 

8.3 ... 250 mbar a

(0.12 ... 3.63 psi a)

D

 

43 ... 1300 mbar a

(0.62 ... 18.9 psi a)

F

 

0.16 ... 5 bar a

(2.32 ... 72.5 psi a)

G

 

1 ... 30 bar a

(14.5 ... 435 psi a)

H

 

Wetted parts materials

 

 

 

Seal diaphragm

Process connection

 

 

Stainless steel

Stainless steel

A

 

Hastelloy

Stainless steel

B

 

Hastelloy

Hastelloy

C

 

Version for diaphragm seal2)3)4)

Y

 

Process connection

 

 

 

• Connection shank G½B to EN 837-1

0

 

• Female thread ½-14 NPT

1

 

• Oval flange made of stainless steel

 

 

- Mounting thread 7/16-20 UNF to EN 61518

2

 

- Mounting thread M10 to DIN 19213

3

 

• Male thread M20 x 1,5

 

5

 

• Male thread ½-14 NPT

 

6

 

Non-wetted parts materials

 

 

• Housing made of die-cast aluminium

0

 

• Housing stainless steel precision casting5)

3

 

Version

 

 

 

• Standard version

 

 

1

• International version, English label inscriptions,

 

2

documentation in 5 languages on CD

 

 

Explosion protection

 

 

 

• Without

 

 

A

• With ATEX, Type of protection:

 

 

- "Intrinsic safety (EEx ia)"

 

B

- "Explosion-proof (EEx d)"6)

 

D

- "Intrinsic safety and explosion-proof enclosure

 

P

(EEx ia + EEx d)"7)

 

 

 

- "Ex nA/nL (zone 2)"

 

 

E

- "Intrinsic safety, explosion-proof enclosure and

 

R

dust explosion protection (EEx ia + EEx d +

 

 

Zone 1D/2D)"7)

 

 

 

• With FM + CSA, Type of protection:

 

 

- "Intrinsic safety and explosion-proof

 

N C

(is + xp)"6)

 

 

 

Electrical connection / cable entry

 

 

• Screwed gland Pg 13.58)

 

A

• Screwed gland M20x1.5

 

B

• Screwed gland ½-14 NPT

 

C

• Han 7D plug (plastic housing) incl. mating

 

 

 

D

connector8)

 

 

• Plug M12 (metal)9)

 

F

Selection and Ordering data

Order No.

 

SITRANS P pressure transmitters for absolute F)

7 M F

4 2 3 3

-

 

 

 

 

pressure, from the pressure series DS III HART

 

 

 

 

 

 

 

 

 

 

 

 

77777

 

-

 

7777

 

 

 

 

 

 

 

 

 

 

 

 

Display

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Without indicator

 

 

 

 

 

 

 

0

 

 

2

• Without visible digital indicator (digital indicator }

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

hidden, setting: mA)

 

 

 

 

 

 

 

 

 

 

 

• With visible digital indicator

 

 

 

 

 

 

 

6

 

 

 

• With customer-specific digital indicator (setting

 

 

 

 

 

 

 

7

 

 

 

as specified, Order code "Y21" or required)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power supply units see "SITRANS I power supply units and isolation amplifiers".

Factory-mounting of shut-off valves and valve manifolds see page 2/142.

Included in delivery of the device:

Brief instructions (Leporello)

CD-ROM with detailed documentation

1)For oxygen application, add Order code E10.

2)Version 7MF4233-1DY... only up to max. span 200 mbar a (2.9 psi a)

3)When the manufacture’s certificate M (calibration certificate) has to be ordered for transmitters with diaphragm seals, it is recommended only to order this certificate exclusively with the diaphragm seals. The measuring accuracy of the total combination is certified here.

4)Whe the acceptance test certificate 3.1 for transmitters with direct-con- nected diaphragm seals is ordered, this certificate must also be ordered with the corresponding seals.

5)Not together with Electrical connection „Screwed gland Pg 13.5“ and „Han7D plug“.

6)Without cable gland, with blanking plug.

7)With enclosed cable gland EEx ia and blanking plug.

8)Not together with type of protection "Explosion-proof" and type of protection "Ex nA".

9)Not together with types of protection "Explosion-proof" or "Intrinsic safety and explosion-proof"

F) Subject to export regulations AL: 9I999, ECCN: N.

Siemens FI 01 · 2009

2/93

Page 93
Image 93
Siemens technical specifications Selection and Ordering data Order No, Pressure, from the pressure series DS III Hart