© Siemens AG 2008

SITRANS P measuring instruments for pressure

Transmitters for gage pressure for the paper industry

SITRANS P300 with PMC connection

Selection and Ordering data

Order No.

SITRANS P300 pressure transmitters with PMC connection, single-chamber measuring housing, rating plate inscription in English

4 ... 20 mA/HART

 

F)

7 M F 8 1 2 3 -

PROFIBUS PA

 

F)

7 M F 8 1 2 4 -

FOUNDATION Fieldbus (FF)

F)

7 M F 8 1 2 5 -

 

 

 

77777 -

7777

Measuring cell filling

Measuring cell cleaning

 

 

 

Silicone oil

Standard

 

1

 

Inert liquid

Cleanliness level 2 to

 

3

 

 

DIN 25410

 

 

 

Span

 

 

 

 

1 bar g

(14.5 psi g)

 

B

 

4 bar g

(58 psi g)

 

C

 

16 bar g

(232 psi g)

 

D

 

Wetted parts materials

 

 

 

 

Seal diaphragm

Measuring cell

 

 

 

Hastelloy

Stainless steel

 

B

 

Process connection

 

 

 

 

• PMC Style Standard: Thread 1½"

 

2

 

• PMC Style Mini bolt: 1" front-flush (min. span: 500

 

3

 

mbar (7.25 psi), can not be ordered with mit 1-bar

 

 

 

(14.5 psi) measuring cell (Option B))

 

 

 

Non-wetted parts materials

 

 

 

• Stainless steel, deep-drawn and electrolytically

 

4

 

polished

 

 

 

 

Version

 

 

 

 

• Standard version

 

 

 

1

Explosion protection

 

 

 

 

• None

 

 

 

A

• With ATEX, Type of protection:

 

 

 

- "Intrinsic safety (EEx ia)"

 

 

B

• Zone 20/21/221)

 

 

 

C

• Ex nA/nL (zone 2)2)

 

 

 

E

• With FM + CSA, Type of protection:

 

 

 

- "Intrinsic Safe (is)" (planned)

 

 

M

Electrical connection / cable entry

 

 

 

• Screwed gland M20x1.5 (Polyamide)3)

 

 

A

• Screwed gland M20x1.5 (metal)

 

 

B

• Screwed gland M20x1.5 (stainless steel)

 

 

C

• M12 connector (without cable socket)

 

 

F

• M12 connector (stainless steel, without cable socket)

 

G

½-14 NPT thread, metal4)

 

 

H

½-14 NPT thread, stainless steel4)

 

 

J

Display

 

 

 

 

• Without display, with keys, closed lid3)

 

 

1

• With display and keys, closed lid

 

 

2

 

 

 

• With display and keys, lid with glass pane

 

 

6

 

 

 

(setting on HART devices: mA, on PROFIBUS PA

 

 

 

and FOUNDATION Fieldbus devices: pressure unit)

 

 

• With display (setting acc. to specifications, Order

 

 

7

 

 

 

code "Y21" or "Y22" required), lid with glass pane

 

 

 

Power supply units see "SITRANS I power supply units and isolation amplifiers".

Included in delivery of the device:

Brief instructions (Leporello)

CD-ROM with detailed documentation

Sealing ring

1)Can only be ordered in conjunction with electrical connection Option A.

2)Can only be ordered in conjunction with electrical connection Option B, C, F or G.

3)Only together with HART electronics.

4)Without cable gland.

F) Subject to export regulations AL: 9I999, ECCN: N.

 

 

Selection and Ordering data

 

Order code

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Further designs

 

 

 

 

 

HART

PA

FF

 

 

 

 

Add "-Z" to Order No. and specify Order

 

 

 

 

 

 

 

 

 

code.

 

 

 

 

 

 

 

 

 

 

 

 

 

Cable socket for M12 plug

 

 

 

 

 

 

 

2

 

 

• Metal

 

 

 

 

A50

 

￿

￿

 

 

 

 

 

 

 

 

 

 

 

• Stainless steel

 

 

 

 

A51

 

￿

￿

 

 

 

 

Rating plate inscription

 

 

 

 

 

 

 

 

 

 

 

 

(instead of English)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• German

 

 

 

 

B10

￿

￿

￿

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• French

 

 

 

 

B12

￿

￿

￿

 

 

 

 

• Spanish

 

 

 

 

B13

￿

￿

￿

 

 

 

 

• Italian

 

 

 

 

B14

￿

￿

￿

 

 

 

 

English rating plate

 

 

 

B21

￿

￿

￿

 

 

 

 

Pressure units in inH2O or psi

 

 

 

 

 

 

 

 

 

 

Quality inspection certificate (Factory cali-

C11

 

 

 

 

 

 

 

￿

￿

￿

 

 

 

 

bration) to IEC 60770-2

 

 

 

 

 

 

 

 

 

 

 

 

Acceptance test certificate

 

C12

￿

￿

￿

 

 

 

 

To EN 10204-3.1

 

 

 

 

 

 

 

 

 

 

 

 

 

Factory certificate

 

 

 

C14

 

 

 

 

 

 

 

 

 

 

￿

￿

￿

 

 

 

 

To EN 10204-2.2

 

 

 

 

 

 

 

 

 

 

 

 

 

Set output signal to upper limit of 22.0 mA

D05

 

 

 

 

 

 

 

￿

￿

￿

 

 

 

 

Type of protection IP68

 

 

 

D12

￿

￿

￿

 

 

 

 

Mounting

 

 

 

 

 

 

 

 

 

 

 

 

 

• Weldable sockets for standard 1½" threaded

 

 

 

 

 

 

 

P01

￿

￿

￿

 

 

 

 

 

connection

 

 

 

 

 

 

 

 

 

 

 

 

 

• Weldable socket for mini bolt connection 1"

P02

￿

￿

￿

 

 

 

 

(incl. screw 5/16-18 UNC-2B and washer)

 

 

 

 

 

 

 

 

 

Additional data

 

 

 

 

 

 

 

 

 

 

 

 

 

Add "-Z" to Order No. and

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

specify Order code.

 

 

 

 

 

 

 

 

 

 

 

 

Measuring range to be set

 

Y01

￿

 

 

 

 

 

 

 

Specify in plain text (max. 5 digits):

 

 

 

 

 

 

 

 

 

Y01: ... up to ... mbar, bar, kPa, MPa, psi

 

 

 

 

 

 

 

 

 

Measuring point number (TAG No.)

Y15

 

 

 

 

 

 

 

￿

￿

￿

 

 

 

 

Max. 16 characters, specify in plain text: Y15:

 

 

 

 

 

 

 

 

......

 

 

 

 

 

 

 

 

 

 

 

 

 

Measuring point text

 

 

 

Y16

 

 

 

 

 

 

 

 

 

 

￿

￿

￿

 

 

 

 

Max. 27 characters, specify in plain text: Y16:

 

 

 

 

 

 

 

 

......

 

 

 

 

 

 

 

 

 

 

 

 

 

Entry of HART address (TAG)

 

Y17

￿

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Max. 8 characters, specify in plain text:

 

 

 

 

 

 

 

 

 

Y17:

 

 

 

 

 

 

 

 

 

 

Setting of pressure indication in pressure

Y21

 

 

 

 

 

 

 

￿

￿

￿

 

 

 

 

units

 

 

 

 

 

 

 

 

 

 

 

 

 

Specify in plain text (standard setting: mA):

 

 

 

 

 

 

 

 

 

Y21: mbar, bar, kPa, MPa, psi, ...

 

 

 

 

 

 

 

 

 

 

Note: The following pressure units can be

 

 

 

 

 

 

 

 

 

selected:

 

 

 

 

 

 

 

 

 

 

 

 

 

bar, mbar, mm H

O*), inH

2

O*), ftH

O*),

 

 

 

 

 

 

 

 

2

 

2

 

 

 

 

 

 

 

 

 

 

mmHG, inHG, psi, Pa, kPa, MPa, g/cm2,

 

 

 

 

 

 

 

 

 

kg/cm2, Torr, ATM or %

 

 

 

 

 

 

 

 

 

 

 

 

*) ref. temperature 20 °C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Setting of pressure indication in non-pres-

Y22 +

￿

 

 

 

 

 

 

 

sure units

 

 

 

 

Y01

 

 

 

 

 

 

 

 

Specify in plain text:

 

 

 

 

 

 

 

 

 

 

 

 

Y22: ..... up to ..... l, m3, m, USg, ...

 

 

 

 

 

 

 

 

(specification of measuring range in pressure

 

 

 

 

 

 

 

 

units "Y01" is essential, unit with max. 5 char-

 

 

 

 

 

 

 

 

acters)

 

 

 

 

 

 

 

 

 

 

 

 

 

Preset bus address

 

 

 

Y25

 

 

 

 

 

 

 

 

 

 

 

￿

￿

 

 

 

 

Specify in plain text:

 

 

 

 

 

 

 

 

 

 

 

 

Y25:

 

 

 

 

 

 

 

 

 

 

 

 

Only "Y01" and "Y21" can be factory preset

 

 

 

 

 

 

 

 

 

￿ = available

 

 

 

 

 

 

 

 

 

 

 

Siemens FI 01 · 2009

2/61

Page 61
Image 61
Siemens P technical specifications Y22 + Sure units Y01