Siemens P technical specifications Technical specifications

Models: P

1 234
Download 234 pages 4.66 Kb
Page 98
Image 98

© Siemens AG 2008

SITRANS P measuring instruments for pressure

Transmitters for gage, absolute and differential pressure, flow and level

DS III series for absolute pressure (from differential pressure series)

Technical specifications

SITRANS P, DS III series for absolute pressure (from differential pressure series)

 

 

 

HART

 

 

 

PROFIBUS PA or FOUNDATION Fieldbus

 

 

 

 

 

 

 

 

 

 

2

 

Input

 

 

 

 

 

 

 

 

Measured variable

Absolute pressure pressure

 

 

 

 

 

 

Spans (infinitely adjustable) or

Span

 

Maximum working pres-

 

Nominal measuring

 

Maximum working pres-

 

 

 

 

 

 

 

nominal measuring range and

 

 

sure

 

range

 

sure

 

 

max. permissible working pressure

 

 

 

 

 

 

 

 

 

 

8.3 ... 250 mbar a

 

32 bar a

 

250 mbar a

 

32 bar a

 

 

 

 

 

 

(0.12 ... 3.6 psi a)

 

(464 psi a)

 

(3.6 psi a)

 

(464 psi a)

 

 

 

43 ... 1300 mbar a

 

32 bar a

 

1300 bar a

 

32 bar a

 

 

 

(0.62 ... 18.9 psi a)

 

(464 psi a)

 

(18.9 psi a)

 

(464 psi a)

 

 

 

160 ... 5000 mbar a

 

32 bar a

 

5 bar a

 

32 bar a

 

 

 

(2.32 ... 72.5 psi a)

 

(464 psi a)

 

(72.5 psi a)

 

(464 psi a)

 

 

 

1 ... 30 bar a

 

160 bar a

 

30 bar a

 

160 bar a

 

 

 

(14.5 ... 435 psi a)

 

(2320 psi a)

 

(435 psi a)

 

(2320 psi a)

 

 

 

5.3 ... 100 bar a

 

160 bar a

 

100 bar a

 

160 bar a

 

 

 

(77 ... 1450 psi a)

 

(2320 psi a)

 

(1450 psi a)

 

(2320 psi a)

 

 

 

 

 

(for connection thread

 

 

 

(for connection thread

 

 

 

 

 

M10 and 7/16-20 UNF in

 

 

 

M10 and 7/16-20 UNF in

 

 

 

 

 

the process flanges)

 

 

 

the process flanges)

 

 

Lower measuring limit

 

 

 

 

 

 

 

 

 

• Measuring cell with silicone oil filling

0 mbar a (0 psi a)

 

 

 

 

 

 

 

 

Upper measuring limit

100% of max. span

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output

 

 

 

 

 

 

 

 

 

Output signal

4 ... 20 mA

 

 

 

Digital PROFIBUS PA or FOUNDATION Fieldbus

 

 

 

 

 

 

 

signal

 

 

 

 

• Lower limit (infinitely adjustable)

3.55 mA, factory preset to 3.84 mA

 

-

 

 

 

 

• Upper limit (infinitely adjustable)

23 mA, factory preset to 20.5 mA or optionally set

 

-

 

 

 

 

 

to 22.0 mA

 

 

 

 

 

 

 

 

Load

 

 

 

 

 

 

 

 

 

• Without HART communication

RB (UH - 10.5 V)/0.023 A in Ω,

 

 

 

 

 

 

-

 

 

 

 

 

UH : Power supply in V

 

 

 

 

 

 

 

 

• With HART communication

RB = 230 ... 500 Ω (SIMATIC PDM) or

 

-

 

 

 

 

 

RB = 230 ... 1100 Ω (HART Communicator)

 

 

 

 

 

 

Physical bus

-

 

 

 

IEC 61158-2

 

 

 

 

With polarity reversal protection

-

 

 

 

Yes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Accuracy

To EN 60770-1

 

 

 

 

 

 

 

 

Reference conditions

Increasing characteristic, start-of-scale value 0 bar, stainless steel seal diaphragm, silicone oil filling,

 

 

(All error data refer always refer to the set

room temperature 25 °C (77 °F)) r: Span ratio (r = max. span / set span)

 

 

 

 

span)

 

 

 

 

 

 

 

 

 

Error in measurement and fixed-point setting

 

 

 

 

 

 

 

 

 

(including hysteresis and repeatability)

 

 

 

 

 

 

 

 

 

• Linear characteristic

 

 

 

 

0.1%

 

 

 

 

 

 

 

 

 

 

 

 

- r 10

0.1%

 

 

 

 

 

 

 

 

- 10 < r 30

0.2%

 

 

 

 

 

 

 

 

Long-term drift (temperature change ± 30 °C

(0.1 r)%/year

 

 

 

0.1%/year

 

 

 

 

(± 54 °F))

 

 

 

 

 

 

 

 

 

Influence of ambient temperature

 

 

 

 

 

 

 

 

 

• at -10 ... +60 °C (14 ... 140 °F)

(0.1 r +0.2)%

 

 

 

0.3%

 

 

 

 

 

 

 

 

 

 

 

• at -40 ... -10 °C and +60 ... +85 °C

(0.1 r + 0.15)%/10 K

 

 

 

0.25%/10 K

 

 

 

 

(-40 ... +14 °F and 140 ... 185 °F)

 

 

 

 

 

 

 

 

 

Measured Value Resolution

-

 

 

 

3 10-5of nominal measuring range

2/98

Siemens FI 01 · 2009

Page 98
Image 98
Siemens P technical specifications Technical specifications