Siemens P With metal measuring cell, Mbar g psi g1, Up to Bar psi g1, For absolute pressure

Models: P

1 234
Download 234 pages 4.66 Kb
Page 9
Image 9

© Siemens AG 2008

SITRANS P measuring instruments for pressure

Transmitters for gage, absolute and differential pressure

Z series for gage and absolute pressure

 

Selection and Ordering data

 

 

 

 

 

 

 

 

 

 

Order No.

 

 

 

 

 

 

 

 

Order code

 

 

 

SITRANS P pressure transmitters for pressure, series Z for gage and absolute pressure

 

D)

7 MF

1 5 6 4

-

 

77777

 

-

7

77

1

777

 

 

 

 

 

2 or 3-wire system, rising characteristic curve

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Measuring range

 

 

 

perm. working pressure

 

 

Burst pressure

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

Min.

 

 

Max.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

For gage pressure

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

with metal measuring cell

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

100 mbar g

(0

1.45 psi g)

 

-0,6 bar g

(-8.7 psi g)

 

0,6 bar g

(8.7 psi g)

 

1 bar g

(14.5 psi g)

}

 

 

 

3

A A 0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

160 mbar g

(0

2.32 psi g)

 

-0,6 bar g

(-8.7 psi g)

 

0,6 bar g

(8.7 psi g)

 

1 bar g

(14.5 psi g)

}

 

 

 

3

A B 0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0 ...

250 mbar g

(0 ...

3.63 psi g)

 

-1 bar g

(-14.5 psi g)

 

1 bar g

(14.5 psi g)

 

1.7 bar g

(25 psi g)

}

 

 

 

3

A C 0

 

 

 

 

 

 

 

 

 

 

0

400 mbar g

(0

5.80 psi g)

 

-1 bar g

(-14.5 psi g)

 

1 bar g

(14.5 psi g)

 

1.7 bar g

(25 psi g)

}

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

A

D

0

 

 

 

 

 

 

 

 

 

 

0 ...

600 mbar g

(0 ...

8.70 psi g)

 

-1 bar g

(-14.5 psi g)

 

3 bar g

(43.5 psi g)

 

5 bar g

(72 psi g)

}

 

 

 

3

AG

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Other version for measuring range < 1 bar (< 14.5 psi g), add Order code and plain text:

 

 

 

 

 

9

A C

0

 

 

 

 

 

 

H 1 Y

 

 

 

 

 

measuring range: ...

up to ...

mbar g (psi g)1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

with ceramic measuring cell

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

1 bar g

(0 ...

14.5 psi g)

 

-0,4 bar g

(-5.8 psi g)

 

2 bar g

(30 psi g)

 

5 bar g

(72 psi g)

}

 

 

 

3

B A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0 ...

1.6 bar g

(0 ...

23.2 psi g)

 

-0,4 bar g

(-5.8 psi g)

 

3,2 bar g

(45 psi g)

 

5 bar g

(72 psi g)

}

 

 

 

3

B B

 

 

 

 

 

 

 

 

 

 

 

0 ...

2.5 bar g

(0 ...

36.3 psi g)

 

-0,8 bar g

(-11.6 psi g)

 

5 bar g

(72 psi g)

 

12 bar g

(175 psi g)

}

 

 

 

3

B D

 

 

 

 

 

 

 

 

 

 

 

0 ...

4 bar g

(0 ...

58.0 psi g)

 

-0,8 bar g

(-11.6 psi g)

 

8 bar g

(115 psi g)

 

12 bar g

(175 psi g)

}

 

 

 

3

B E

 

 

 

 

 

 

 

 

 

 

 

0 ...

6 bar g

(0 ...

87.0 psi g)

 

-1 bar g

(-14.5 psi g)

 

12 bar g

(175 psi g)

 

25 bar g

(360 psi g)

}

 

 

 

3

BG

 

 

 

 

 

 

 

 

 

 

 

0 ...

10 bar g

(0 ...

145 psi g)

 

-1 bar g

(-14.5 psi g)

 

20 bar g

(290 psi g)

 

50 bar g

(725 psi g)

}

 

 

 

3

C A

 

 

 

 

 

 

 

 

 

 

 

0 ...

16 bar g

(0 ...

232 psi g)

 

-1 bar g

(-14.5 psi g)

 

32 bar g

(460 psi g)

 

50 bar g

(725 psi g)

}

 

 

 

3

C B

 

 

 

 

 

 

 

 

 

 

 

0 ...

25 bar g

(0 ...

363 psi g)

 

-1 bar g

(-14.5 psi g)

 

50 bar g

(725 psi g)

 

120 bar g

(1750 psi g) }

 

 

 

3

C D

 

 

 

 

 

 

 

 

 

 

 

0 ...

40 bar g

(0 ...

580 psi g)

 

-1 bar g

(-14.5 psi g)

 

80 bar g

(1150 psi g)

 

120 bar g

(1750 psi g) }

 

 

 

3

C E

 

 

 

 

 

 

 

 

 

 

 

0 ...

60 bar g

(0 ...

870 psi g)

 

-1 bar g

(-14.5 psi g)

 

120 bar g

(1750 psi g)

 

250 bar g

(3600 psi g) }

 

 

 

3

CG

 

 

 

 

 

 

 

 

 

 

 

0 ...

100 bar g

(0 ...

1450 psi g)

 

-1 bar g

(-14.5 psi g)

 

200 bar g

(2900 psi g)

 

450 bar g

(6525 psi g) }

 

 

 

3

D A

 

 

 

 

 

 

 

 

 

 

 

0 ...

160 bar g

(0 ...

2320 psi g)

 

-1 bar g

(-14.5 psi g)

 

320 bar g

(4640 psi g)

 

450 bar g

(6525 psi g) }

 

 

 

3

D B

 

 

 

 

 

 

 

 

 

 

 

0 ...

250 bar g

(0 ...

3626 psi g)

 

-1 bar g

(-14.5 psi g)

 

500 bar g

(7250 psi g)

 

650 bar g

(9425 psi g) }

 

 

 

3

D D

 

 

 

 

 

 

 

 

 

 

 

0 ...

400 bar g

(0 ...

5802 psi g)

 

-1 bar g

(-14.5 psi g)

 

600 bar g

(8700 psi g)

 

650 bar g

(9425 psi g) }

 

 

 

3

D E

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Other version for measuring range 1 bar g (14.5 psi g), add Order code and plain text:

 

 

 

 

 

9

A A

 

 

 

 

 

 

 

H 1 Y

 

 

 

 

measuring range: ...

up to...

bar (psi g)1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

For absolute pressure

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0 ...

600 mbar a

(0 ...

8.7 psi a)

 

0 bar a

(0 psi a)

 

3 bar a

(43.5 psi a)

 

5 bar a

(72 psi a)

}

J)

 

 

5

AG

0

 

 

 

 

 

 

 

 

 

 

...0

1 bar a

...(0

 

0 bar a

(0 psi a)

 

2 bar a

(30 psi a)

 

5 bar a

(72 psi a)

}

J)

 

 

5

B A

 

 

 

 

 

 

 

 

 

 

 

0 ...

1.6 bar a

(0 ...

23.2 psi a)

 

0 bar a

(0 psi a)

 

3,2 bar a

(45 psi a)

 

5 bar a

(72 psi a)

}

J)

 

 

5

B B

 

 

 

 

 

 

 

 

 

 

 

0 ...

2.5 bar a

(0 ...

36.3 psi a)

 

0 bar a

(0 psi a)

 

5 bar a

(72 psi a)

 

12 bar a

(175 psi a)

}

J)

 

 

5

B D

 

 

 

 

 

 

 

 

 

 

 

0 ...

4 bar a

(0 ...

58.0 psi a)

 

0 bar a

(0 psi a)

 

8 bar a

(115 psi a)

 

12 bar a

(175 psi a)

}

J)

 

 

5

B E

 

 

 

 

 

 

 

 

 

 

 

0 ...

6 bar a

(0 ...

87.0 psi a)

 

0 bar a

(0 psi a)

 

12 bar a

(175 psi a)

 

25 bar a

(360 psi a)

}

J)

 

 

5

BG

 

 

 

 

 

 

 

 

 

 

 

0 ...

10 bar a

(0 ...

145 psi)

 

0 bar a

(0 psi a)

 

20 bar a

(290 psi a)

 

50 bar a

(725 psi a)

}

J)

 

 

5

C A

 

 

 

 

 

 

 

 

 

 

 

0 ...

16 bar a

(0 ...

232 psi)

 

0 bar a

(0 psi a)

 

32 bar a

(460 psi a)

 

50 bar a

(725 psi a)

}

J)

 

 

5

C B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Other version for measuring range < 1 bar (< 14.5 psi a), add Order code and plain text:

 

 

J)

 

 

9

A B

0

 

 

 

 

 

 

H 1 Y

 

 

 

 

 

measuring range: ...

up to ...

mbar a (psi a)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

} Available ex stock

 

 

D) Subject to export regulations AL: N, ECCN: EAR99H.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

J)Subject to export regulations AL: 9I999, ECCN: EAR99.

1)The transmitters can also be ordered with special measuring ranges, e.g. the transmitter with the 1 bar measuring cell (14.5 psi measuring cell):

-0.2 ... +0.8 bar g (-2.9 ... +11.6 psi g) or

-0.4 ... +0.6 bar g (-5.8 ... +8.7 psi g) or ..., however start-of-scale value not under -0.4 bar g (-5.8 psi g), also see column "min. perm. operating pressure"

Please note:

It is not possible to have a smaller span than the smallest span of the device of the entire device range.

The value must not fall below the minimum permissible operating pressure of the special measuring range of the selected measuring cell.

The required span of the device must lie between the smallest and the largest possible span of the entire device range.

Siemens FI 01 · 2009

2/9

Page 9
Image 9
Siemens P technical specifications With metal measuring cell, Mbar g psi g1, Up to Bar psi g1, For absolute pressure