Siemens P technical specifications ZD series for gage and absolute pressure, Functions

Models: P

1 234
Download 234 pages 4.66 Kb
Page 17
Image 17

© Siemens AG 2008

SITRANS P measuring instruments for pressure

 

Transmitters for gage, absolute and differential pressure

 

 

 

 

ZD series for gage and absolute pressure

 

 

 

 

At the rear of the housing is the electrical connection for the volt-

 

Overview

 

 

 

 

 

age supply using a current loop 4 ... 20 mA. The connection is

 

 

 

 

made with a plug connector.

 

 

 

 

At the front of the housing is the 5-digit display behind a glass

 

 

 

 

cover. Underneath the display are the 3 keys for parameterizing

 

 

 

 

the pressure transmitter. Above the display are a green and a red

2

 

 

 

LED for indicating the operating status.

The ZD pressure transmitter is available in two versions (see "Di- mension drawing"):

In the radial version (type A) the display is fitted in parallel with the process connection. The display can be rotated by up to

±120° relative to the process connection.

In the axial version (type B) the display is at right angles to the process connection. The display can be rotated by 360° relative to the process connection.

Function

Green LED

Red LED

Uref

LCD

SITRANS P pressure transmitters, ZD series, are for measuring the gage pressure, absolute pressure and level of liquids and gases.

They are used to indicate and monitor the pressure measured at the point of installation. ZD pressure transmitters are available in an axial and a radial version.

P A/D

EEP RO M

D/A

 

µC

 

 

UK

 

UA

U

I

 

 

600.00

mbar

3keys

EMC+

4 ... 20 mA - UH, IA

Benefits

Robust stainless steel housing with 2 connection versions

Integrated display with status messages

Thin-film measuring cell with ceramic diaphragm

2-wire system, 4 ... 20 mA

Parameterizable using keys underneath the housing cover

Range adjustment 1:5 (max. 1:10)

Measuring accuracy < 0.25% (typical)

Application

The ZD is a configurable pressure transmitter for measuring the gage and absolute pressure of gases, liquids and vapor.

It is equipped with a display for indicating the pressure value at the point of installation.

SITRANS P pressure transmitters, ZD series, are used in the fol- lowing industrial areas for example:

Chemical industry

Mechanical engineering

Food industry

Pharmaceutical industry

Shipbuilding

Water supply

Design

The pressure transmitter is comprised of a thin-film measuring cell with a ceramic diaphragm, an electronics board and a digi- tal indicator.

All parts are accommodated in a stainless steel field housing (80 mm) with a glass cover and stainless steel process con- nection.

3 keys

Configuring of parameters

A/D

Analog-to-digital converter

D/A

Digital-to-analog converter

EEPROM

Memory for all parameters

EMC

Output stage with protective components

IA

Output current

Uref

Reference voltage

LCD

Display of measured values with dimensions

Green LED

Display of normal mode

Red LED

Display of error messages or limit violation

PCeramic measuring cell

UH

Power supply

µC

Microcontroller for computing functions and monitoring

SITRANS P pressure transmitters, ZD series, mode of operation

Mode of operation

The ZD pressure transmitter has a thin-film strain gage which is mounted on a ceramic diaphragm.

The measuring cell is temperature-compensated.

Functions

The ZD pressure transmitter has a 5-digit display behind a glass cover. The following data are shown on the display:

Measured pressure

Technical pressure dimension (default setting: bar)

Limit violation in upward or downward direction, indicated by LED and arrow symbols in the display

The pressure transmitter is set using the 3 input keys behind the glass cover underneath the display.

The key "M" is used to select the operating mode. Following modes of operation are available:

Measured value

Password

Dimension

Start and end of scale

Upper and lower limit value

Zero adjustment

Siemens FI 01 · 2009

2/17