© Siemens AG 2008

SITRANS P measuring instruments for pressure

Transmitters for food, pharmaceuticals and biotechnology

SITRANS P300 for gage and absolute pressure

Selection and Ordering data

Order code

 

 

Further designs

 

HART

PA

FF

Add "-Z" to Order No. and specify Order

 

 

 

 

code.

 

 

 

 

Mounting bracket

A02

￿

￿

￿

made completely of stainless steel, for wall or

 

 

 

 

pipe mounting

 

 

 

 

Cable socket for M12 plug

 

 

 

 

 

 

 

 

• Metal

A50

 

￿

￿

 

• Stainless steel

A51

 

￿

￿

Rating plate inscription

 

 

 

 

 

 

 

 

(instead of English)

 

 

 

 

• German

B10

￿

￿

￿

• French

B12

￿

￿

￿

• Spanish

B13

￿

￿

￿

• Italian

B14

￿

￿

￿

English rating plate

B21

￿

￿

￿

Pressure units in inH20 or psi

 

 

 

 

 

 

 

 

Quality inspection certificate (Factory cali-

C11

￿

￿

￿

bration) to IEC 60770-21)

 

 

 

 

to IEC 60770-2

 

 

 

 

 

 

 

 

Acceptance test certificate2)

C12

 

 

 

￿

￿

￿

to EN 10204-3.1

 

 

 

 

 

 

 

 

Factory certificate

C14

 

 

 

￿

￿

￿

to EN 10204-2.2

 

 

 

 

 

 

 

 

 

 

 

 

 

Type of protection IP68

D12

￿

￿

￿

Only for SITRANS P300 with front-flush

 

 

 

 

diaphragm (7MF81..-...)

 

 

 

 

Flange to EN 1092-1, form B1

 

 

 

 

• DN 25, PN 403)

M11

￿

￿

￿

• DN 25, PN 1003)

M21

￿

￿

￿

• DN 40, PN 40

M13

￿

￿

￿

• DN 40, PN 100

M23

￿

￿

￿

• DN 50, PN 16

M04

￿

￿

￿

• DN 50, PN 40

M14

￿

￿

￿

• DN 80, PN 25

M06

￿

￿

￿

• DN 80, PN 40

M16

￿

￿

￿

Flanges to ASME B16.5

 

 

 

 

 

 

 

 

• 1", class 1503)

 

 

 

 

M40

￿

￿

￿

• 1½", class 150

M41

￿

￿

￿

• 2", class 150

M42

￿

￿

￿

• 3", class 150

M43

￿

￿

￿

• 4", class 150

M44

￿

￿

￿

• 1", class 3003)

M45

￿

￿

￿

• 1½", class 300

 

 

 

 

M46

￿

￿

￿

• 2", class 300

M47

￿

￿

￿

• 3", class 300

M48

￿

￿

￿

Threaded connection acc. to DIN 3852-2,

 

 

 

 

 

 

 

 

Form A

 

 

 

 

• G ¾“-A, flush-mounted4)

R01

￿

￿

￿

• G 1“-A, flush-mounted4)

 

 

 

 

R02

￿

￿

￿

• G 2“-A, flush-mounted4)

R04

￿

￿

￿

Tank connection5)

 

 

 

 

Sealing is included in delivery

 

 

 

 

• TG 52/50, PN 40

 

 

 

 

R10

￿

￿

￿

• TG 52/150, PN 40

R11

￿

￿

￿

Sanitary process connection according

 

 

 

 

 

 

 

 

DIN 11851 (Dairy connection)

 

 

 

 

certified to 3A6)

 

 

 

 

• DN 50, PN 25

 

 

 

 

N04

￿

￿

￿

• DN 80, PN 25

N06

￿

￿

￿

Tri-Clamp connection according

 

 

 

 

 

 

 

 

DIN 32676/ISO 2852

 

 

 

 

certified to 3A6)

 

 

 

 

• DN 50/2“, PN 16

N14

￿

￿

￿

• DN 65/3“, PN 10

N15

￿

￿

￿

 

 

 

 

 

Selection and Ordering data

Order code

 

 

 

 

 

Further designs

 

HART

PA

FF

 

 

Add "-Z" to Order No. and specify Order

 

 

 

 

 

 

 

code.

 

 

 

 

 

 

 

Varivent connection

 

 

 

 

 

 

 

certified to 3A and EHEDG3)

 

 

 

 

 

 

2

• Type N = 68 for Varivent housing

N28

￿

￿

￿

 

 

 

 

DN 40 ... 125 and 1½" ... 6", PN 40

 

 

 

 

 

 

 

Temperature decoupler up to 200 °C7)

P00

￿

￿

￿

 

 

for version with front-flush diaphragm

 

 

 

 

 

 

 

Temperature decoupler up to 250 °C

P10

￿

￿

￿

 

 

 

 

Measuring cell filling: High-temperature oil,

 

 

 

 

 

 

 

only in conjunction with measuring cell filling

 

 

 

 

 

 

 

silicone oil

 

 

 

 

 

 

 

Bio-Control (Neumo) sanitary connection

 

 

 

 

 

 

 

certified to 3A and EHEDG3)

 

 

 

 

 

 

 

• DN 50, PN 16

Q53

￿

￿

￿

 

 

 

 

 

• DN 65, PN 16

Q54

￿

￿

￿

 

 

Sanitary process connection to DRD

 

 

 

 

 

 

 

• 65 mm, PN 40

M32

￿

￿

￿

 

 

 

 

 

SMS socket with union nut

 

 

 

 

 

 

 

• 2“

M67

￿

￿

￿

 

 

 

 

 

• 2½“

M68

￿

￿

￿

 

 

• 3“

M69

￿

￿

￿

 

 

SMS threaded socket

 

 

 

 

 

 

 

• 2“

M73

￿

￿

￿

 

 

 

 

 

• 2½“

M74

￿

￿

￿

 

 

• 3“

M75

￿

￿

￿

 

 

IDF socket with union nut ISO 2853

 

 

 

 

 

 

 

• 2“

M82

￿

￿

￿

 

 

 

 

 

• 2½“

M83

￿

￿

￿

 

 

• 3“

 

 

 

 

 

 

M84

￿

￿

￿

 

 

IDF threaded socket ISO 2853

 

 

 

 

 

 

 

• 2“

M92

￿

￿

￿

 

 

 

 

 

• 2½“

M93

￿

￿

￿

 

 

• 3“

M94

￿

￿

￿

 

 

Sanitary process connection to

 

 

 

 

 

 

 

NEUMO Bio-Connect screw connection

 

 

 

 

 

 

 

certified to 3A and EHEDG3)

 

 

 

 

 

 

 

• DN 50, PN 16

Q05

￿

￿

￿

 

 

 

 

 

• DN 65, PN 16

Q06

￿

￿

￿

 

 

• DN 80, PN 16

Q07

￿

￿

￿

 

 

• DN 100, PN 16

 

 

 

 

 

 

Q08

￿

￿

￿

 

 

• DN 2“, PN 16

Q13

￿

￿

￿

 

 

• DN 2½“, PN 16

Q14

￿

￿

￿

 

 

• DN 3“, PN 16

Q15

￿

￿

￿

 

 

• DN 4“, PN 16

Q16

￿

￿

￿

 

 

Sanitary process connection to

 

 

 

 

 

 

 

NEUMO Bio-Connect flange connection

 

 

 

 

 

 

 

certified to 3A and EHEDG3)

 

 

 

 

 

 

 

• DN 50, PN 16

Q23

￿

￿

￿

 

 

 

 

 

• DN 65, PN 16

Q24

￿

￿

￿

 

 

• DN 80, PN 16

Q25

￿

￿

￿

 

 

• DN 100, PN 16

Q26

￿

￿

￿

 

 

• DN 2“, PN 16

 

 

 

 

 

 

Q31

￿

￿

￿

 

 

• DN 2½“, PN 16

Q32

￿

￿

￿

 

 

• DN 3“, PN 16

Q33

￿

￿

￿

 

 

• DN 4“, PN 16

Q34

￿

￿

￿

 

 

Sanitary process connection to

 

 

 

 

 

 

 

NEUMO Bio-Connect clamp connection

 

 

 

 

 

 

 

certified to 3A and EHEDG3)

 

 

 

 

 

 

 

• DN 50, PN 16

 

 

 

 

 

 

Q39

￿

￿

￿

 

 

 

• DN 65, PN 10

Q40

￿

￿

￿

 

 

• DN 80, PN 10

Q41

￿

￿

￿

 

 

• DN 100, PN 10

Q42

￿

￿

￿

 

 

• DN 2½“, PN 16

Q48

￿

￿

￿

 

 

• DN 3“, PN 10

Q49

￿

￿

￿

 

 

• DN 4“, PN 10

Q50

￿

￿

￿

 

 

 

 

 

 

 

 

 

 

Siemens FI 01 · 2009