Siemens P Series DS III Hart Measuring cell filling Cleaning, Nominal measuring range

Models: P

1 234
Download 234 pages 4.66 Kb
Page 55
Image 55

© Siemens AG 2008

SITRANS P measuring instruments for pressure

Transmitters for gage pressure for the paper industry

DS III series with PMC connection

Selection and Ordering data

Order No.

SITRANS P pressure transmitters for gage

7 M F 4 1 3 3 -

pressure, with PMC connection

77777 -

7777

series DS III HART

 

 

 

 

Measuring cell filling

Measuring cell

 

 

 

cleaning

 

 

Silicone oil

Standard

1

 

Inert liquid

Grease-free

3

 

Span

 

 

 

0.01 ... 1 bar g1)

(0.15 ... 14.5 psi g)1)

B

 

0.04 ... 4 bar g

(0.58 ... 58 psi g)

C

 

0.16 ... 16 bar g

(2.32 ... 232 psi g)

D

 

Wetted parts materials

 

 

 

Seal diaphragm

Connection shank

 

 

Hastelloy

Stainless steel

B

 

Process connection

 

 

 

• PMC Style Standard: Thread 1½"

2

 

• PMC Style Mini bolt: 1" front-flush (min. span:

3

 

500 mbar (7.25 psi), can not be ordered with mit

 

 

1-bar (14.5 psi) measuring cell (Option B))

 

 

Non-wetted parts materials

 

 

• Housing made of die-cast aluminum

0

 

• Housing stainless steel precision casting

3

 

Version

 

 

 

• Standard version

 

 

1

• International version, English label inscriptions,

 

2

documentation in 5 languages on CD

 

 

Explosion protection

 

 

 

• None

 

 

A

Electrical connection / cable entry

 

 

• Female thread M20x1.5

 

B

• Female thread ½-14 NPT

 

C

• M12 connectors (metal)

 

F

Display

 

 

 

• Without indicator

 

 

0

• Without visible digital indicator (digital indicator }

 

1

hidden, setting: mA)

 

 

 

• With visible digital indication, setting: mA

 

6

• With customer-specific digital indication (setting

 

7

as specified, Order code "Y21" or "Y22"

 

 

required)

 

 

 

Power supply units see "SITRANS I power supply units and isolation amplifiers".

Included in delivery of the device:

Brief instructions (Leporello)

CD-ROM with detailed documentation

Sealing ring

1)Only with "PMC Style Standard" process connection

Selection and Ordering data

Order No.

SITRANS P pressure transmitter for gage pressure, with PMC connection

DS III PA (PROFIBUS PA) series

7 M F 4 1 3 4 -

 

DS III FF series (FOUNDATION Fieldbus)

7 M F 4 1 3 5 -

2

 

 

77777 -

7777

Measuring cell filling

Measuring cell

 

 

 

 

cleaning

 

 

 

Silicone oil

Standard

1

 

 

Inert liquid

Grease-free

3

 

 

Nominal measuring range

 

 

 

1 bar g1)

(14.5 psi g)1)

B

 

 

4 bar g

(58 psi g)

C

 

 

16 bar g

(232 psi g)

D

 

 

Wetted parts materials

 

 

 

 

Seal diaphragm

Connection shank

 

 

 

Hastelloy

Stainless steel

B

 

 

Process connection

 

 

 

 

• PMC Style Standard: front-flush 1½"

2

 

 

• PMC Style Mini bolt: front-flush 1"

3

 

 

(min. span: 500 mbar (7.25 psi), can not be or-

 

 

 

dered with mit 1-bar (14.5 psi) measuring cell

 

 

 

(Option B))

 

 

 

 

Non-wetted parts materials

 

 

 

• Housing made of die-cast aluminum

0

 

 

• Housing stainless steel precision casting

3

 

 

Version

 

 

 

 

• Standard version

 

 

1

 

• International version, English label inscriptions,

 

2

 

documentation in 5 languages on CD

 

 

 

Explosion protection

 

 

 

 

• None

 

 

A

 

Electrical connection / cable inlet

 

 

 

• Screwed gland M20x1.5

 

B

 

• Screwed gland ½-14 NPT

 

C

 

• M12 connectors (metal)

 

F

 

Display

 

 

 

 

• Without indicator

 

 

0

 

• Without visible digital indicator (digital indicator }

 

1

 

hidden, setting: mA)

 

 

 

 

• With visible digital display

 

6

 

• With customer-specific digital display (setting as

 

7

 

specified, Order code "Y21" or required)

 

 

 

Included in delivery of the device:

Brief instructions (Leporello)

CD-ROM with detailed documentation

Sealing ring

1)Only with "PMC Style Standard" process connection

Siemens FI 01 · 2009

2/55

Page 55
Image 55
Siemens P Series DS III Hart Measuring cell filling Cleaning, Nominal measuring range, Electrical connection / cable inlet