SITRANS P measuring instruments for pressure

Transmitters for food, pharmaceuticals and biotechnology

SITRANS P300 for gage and absolute pressure

 

 

Selection and Ordering data

Order No.

 

 

 

Selection and Ordering data

Order No.

 

 

 

 

 

 

 

 

 

SITRANS P300 pressure transmitters for gage and absolute pressure, single-chamber measur- ing housing, rating plate inscription in English

SITRANS P300 pressure transmitters for gage and absolute pressure, single-chamber measur- ing housing, rating plate inscription in English

4 ... 20 mA/HART

 

 

7

M F

8

0

2

3

-

 

 

 

PROFIBUS PA

 

 

7

M F

8

0

2

4

-

 

 

 

FOUNDATION Fieldbus (FF)

 

 

 

 

 

 

 

 

 

 

 

 

 

7 M F

8

0 2

5 -

 

 

 

 

 

 

 

77777

 

-

 

7777

 

 

Measuring cell filling

Measuring cell cleaning

 

 

 

 

 

 

 

 

 

 

 

 

Silicone oil

Standard

 

1

 

 

 

 

 

 

 

 

 

 

Inert liquid

Cleanliness level 2 to

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

 

 

 

 

 

DIN 25410

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

max. span

 

 

 

 

 

 

 

 

 

 

 

 

 

0.01 ... 1 bar g

(0.145 ... 14.5 psi g)

 

 

B

 

 

 

 

 

 

 

 

 

0.04 ... 4 bar g

(0.58 ... 58 psi g)

 

 

C

 

 

 

 

 

 

 

 

 

0.16 ...16 bar g

(2.32 ... 232 psi g)

 

 

D

 

 

 

 

 

 

 

 

 

0.63 ... 63 bar g

(9.14 ... 914 psi g)

 

 

E

 

 

 

 

 

 

 

 

 

1.6 ... 160 bar g

(23.2 ... 2320 psi g)

 

 

F

 

 

 

 

 

 

 

 

 

4 ... 400 bar g

(58 ... 5800 psi g)

 

 

G

 

 

 

 

 

 

 

 

 

2.5 ... 25 mbar a

(0.036 ... 3.63 psi a)

F)

 

Q

 

 

 

 

 

 

 

 

 

13 ... 1300 mbar a

(0.19 ... 18.9 psi a)

F)

 

S

 

 

 

 

 

 

 

 

 

0.05 ... 5 bar a

(0.7 ... 72.5 psi a)

F)

 

T

 

 

 

 

 

 

 

 

 

0.3 ... 30 bar a

(4.35 ... 435 psi a)

F)

 

U

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wetted parts materials

 

 

 

 

 

 

 

 

 

 

 

 

 

Seal diaphragm

Measuring cell

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Stainless steel

Stainless steel

 

 

 

A

 

 

 

 

 

 

 

 

Hastelloy

Stainless steel

F)

 

 

B

 

 

 

 

 

 

 

 

Hastelloy

Hastelloy

F)

 

 

C

 

 

 

 

 

 

 

 

Version for diaphragm seal 1) 2)

 

 

 

Y

 

 

 

 

 

 

 

 

Process connection

 

 

 

 

 

 

 

 

 

 

 

 

 

• G½B to EN 837-1

 

 

 

 

 

0

 

 

 

 

 

 

 

½-14 NPT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

• Oval flange made of stainless steel

 

 

 

 

 

 

 

 

 

 

 

 

- Mounting thread 7/16-20 UNF to EN 61518

 

 

 

 

2

 

 

 

 

 

 

 

- Mounting thread M10 to DIN 19213

 

 

 

 

3

 

 

 

 

 

 

 

- Mounting thread M12 to DIN 19213

 

 

 

 

4

 

 

 

 

 

 

 

• Male thread M20 x 1,5

 

 

 

 

 

5

 

 

 

 

 

 

 

• Male thread ½ -14 NPT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Non-wetted parts materials

 

 

 

 

 

 

 

 

 

 

 

 

• St. steel, deep-drawn and electrolytically polished

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

Version

 

 

 

 

 

 

 

 

 

 

 

 

 

• Standard version

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Explosion protection

 

 

 

 

 

 

 

 

 

 

 

 

 

• Without

 

 

 

 

 

 

 

 

 

A

• With ATEX, Type of protection:

 

 

 

 

 

 

 

 

 

 

 

 

- "Intrinsic safety (EEx ia)"

 

 

 

 

 

 

 

 

B

• Zone 20/21/223)

 

 

 

 

 

 

 

 

 

C

• Ex nA/nL (zone 2)4)

 

 

 

 

 

 

 

 

 

E

• With FM „Intrinsic safe“ (cFMUS)

 

 

 

 

 

 

 

 

M

Electrical connection / cable entry

 

 

 

• Screwed gland M20x1.5 (Polyamide) 5)

 

 

A

• Screwed gland M20x1.5 (metal)

 

 

B

• Screwed gland M20x1.5 (stainless steel)

 

 

C

• M12 connector (metal, without cable socket)

 

 

F

• M12 connector (stainless steel, without cable socket)

 

 

 

 

G

½-14

NPT thread, metal 6)

 

 

H

½-14

NPT thread, stainless steel6)

 

 

J

4 ... 20 mA/HART

7

M

F

8 0 2

3

-

 

 

2

PROFIBUS PA

7

M

F

8 0 2

4

 

-

 

 

 

 

FOUNDATION Fieldbus (FF)

 

 

 

 

 

 

 

 

 

 

 

7 M

F 8 0 2

 

5 -

 

 

 

 

77777

 

-

 

7777

 

 

 

Display

 

 

 

 

 

 

 

 

 

 

 

 

• Without display, with keys, closed lid5)

 

 

 

 

 

 

 

 

 

1

 

 

• With display and keys, closed lid

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

• With display and keys, lid with macrolon washer

 

 

 

 

 

 

 

 

 

4

 

 

(setting on HART devices: mA,

 

 

 

 

 

 

 

 

 

 

 

 

on PROFIBUS PA and FOUNDATION Fieldbus

 

 

 

 

 

 

 

 

 

 

 

 

devices: pressure units)

 

 

 

 

 

 

 

 

 

 

 

 

• With display (setting acc. to specifications, Order

 

 

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

 

 

 

 

code "Y21" or "Y22" required), lid with macrolon

 

 

 

 

 

 

 

 

 

 

 

 

washer

 

 

 

 

 

 

 

 

 

 

 

 

• With display and keys, lid with glass pane

 

 

 

 

 

 

 

 

 

6

 

 

(setting on HART devices: mA, on PROFIBUS and

 

 

 

 

 

 

 

 

 

 

 

 

FOUNDATION Fieldbus devices: pressure units)

 

 

 

 

 

 

 

 

 

 

 

 

• With display (setting acc. to specifications, Order

 

 

 

 

 

 

 

 

 

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

code "Y21" or "Y22" required), lid with glass pane

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power supply units see "SITRANS I power supply units and isol. amplifiers".

Factory-mounting of shut-off valves and valve manifolds see page 2/142.

Included in delivery of the device:

Brief instructions (Leporello)

CD-ROM with detailed documentation

1)When the manufacture’s certificate M (calibration certificate) has to be ordered for transmitters with diaphragm seals, it is recommended only to order this certificate exclusively with the diaphragm seals. The measuring accuracy of the total combination is certified here.

2)Whe the acceptance test certificate 3.1 for transmitters with direct-con- nected diaphragm seals is ordered, this certificate must also be ordered with the corresponding seals.

3)Can only be ordered in conjunction with electrical connection Option A.

4)Can only be ordered in conjunction with electrical connection Option B, C, F or G.

5)Only together with HART electronics.

6)Without cable gland.