© Siemens AG 2008

SITRANS P measuring instruments for pressure

Transmitters for gage, absolute and differential pressure, flow and level

DS III series for differential pressure and flow

 

 

Selection and Ordering data

Order No.

 

 

 

Selection and Ordering data

Order No.

 

 

 

 

 

 

 

 

 

SITRANS P pressure transmitters for differen- tial pressure and flow, Series DS III HART PN 420 (MWP 6092 psi)

SITRANS P pressure transmitters for differen- tial pressure and flow, Series DS III HART PN 420 (MWP 6092 psi)

DS III PA (PROFIBUS PA) series

7 M F 4 5 3 4 -

DS III FF series (FOUNDATION Fieldbus)

7 M F 4 5 3 5 -

 

 

1 7777 - 7777

Nominal measuring range

 

250 mbar

(100.4 inH2O)

D

600 mbar

(240.9 inH2O)

E

1600 mbar

(642.4 inH2O)

F

5 bar

(2008 inH2O)

G

30 bar

(435 psi)

H

Wetted parts materials

 

 

(stainless steel process flanges)

 

Seal diaphragm

Parts of measuring cell

 

Stainless steel

Stainless steel

A

Hastelloy

Stainless steel

B

Gold1)

Gold

L

Process connection

 

 

Female thread ¼-18 NPT with flange connection

 

• Sealing screw opposite process connection

 

- Mounting thread 7/16-20 UNF to EN 61518

3

- Mounting thread M12 to DIN 19213

1

(only for replacement needs)

 

• Venting on side of process flanges. Position of

 

the top vent valve in the process flanges (see

 

dimensional drawing).

 

 

- Mounting thread 7/16-20 UNF to EN 61518

7

- Mounting thread M12 to DIN 19213

5

(only for replacement needs)

 

Non-wetted parts materials

 

Process flange screws

Electronics housing

 

Stainless steel

Die-cast aluminium

2

Stainless steel

Stainless steel precision

3

 

casting

 

Version

 

 

• Standard version

 

1

• International version, English label inscriptions,

2

documentation in 5 languages on CD

 

Explosion protection

 

 

• Without

 

A

• With ATEX, Type of protection:

 

- "Intrinsic safety (EEx ia)"

B

- "Explosion-proof (EEx d)"2)

D

- "Intrinsic safety and explosion-proof

P

enclosure (EEx ia + EEx d)"3)

 

- "Ex nA/nL (zone 2)"

 

E

- "Intrinsic safety, explosion-proof enclosure

R

and dust explosion protection (EEx ia +

 

EEx d + Zone 1D/2D)"3) (not for DS III FF)

 

• With FM + CSA, Type of protection:

 

- "Intrinsic safety and explosion-proof

N C

(is + xp)"2), max PN 360

 

Electrical connection / cable entry

 

 

• Screwed gland M20x1.5

 

 

 

B

• Screwed gland ½-14 NPT

 

C

• Plug M12 incl. mating connector4)

 

F

 

DS III PA (PROFIBUS PA) series

7

M F

4

5 3 4

-

 

 

2

 

DS III FF series (FOUNDATION Fieldbus)

7

M F

4

5 3 5

-

 

 

 

 

 

 

 

 

 

 

1

 

7777

 

-

 

7777

 

 

 

 

 

Display

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Without indicator

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Without visible digital indicator (digital indicator }

 

 

 

 

 

 

 

 

 

1

 

 

 

 

hidden, setting: mA)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• With visible digital indicator

 

 

 

 

 

 

 

 

 

6

 

 

 

 

• With customer-specific digital indicator (setting

 

 

 

 

 

 

 

 

 

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

as specified, Order code "Y21" or required)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Factory-mounting of shut-off valves and valve manifolds see page 2/142.

Included in delivery of the device:

Brief instructions (Leporello)

CD-ROM with detailed documentation

Sealing plug(s) or sealing screw(s) for the process flanges(s)

1)Not together with max. span 600 mbar (240.9 inH2O)

2)Without cable gland, with blanking plug.

3)With enclosed cable gland EEx ia and blanking plug.

4)Not together with types of protection "Explosion-proof" and "Intrinsic safety and explosion-proof"

Siemens FI 01 · 2009

2/117

Page 117
Image 117
Siemens P technical specifications 117, Nominal measuring range