SITRANS P measuring instruments for pressure

Transmitters for gage, absolute and differential pressure, flow and level

DS III series

for differential pressure and flow

 

 

 

 

Selection and Ordering data

Order code

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Further designs

 

HART

PA

FF

 

 

 

 

Add "-Z" to Order No. and specify Order code.

 

 

 

 

 

 

 

 

Pressure transmitter with mounting

 

 

 

 

2

 

 

 

bracket made of:

 

 

 

 

 

 

 

• Steel

A01

￿

￿

￿

 

 

 

 

 

• Stainless steel

A02

￿

￿

￿

 

 

 

 

O-rings for process flanges

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(instead of FPM (Viton))

 

 

 

 

 

 

 

 

• PTFE (Teflon)

A20

￿

￿

￿

 

 

 

 

 

 

 

 

• FEP (with silicone core, approved for food)

A21

￿

￿

￿

 

 

 

 

• FFPM (Kalrez, compound 4079)

A22

￿

￿

￿

 

 

 

 

• NBR (Buna N)

A23

￿

￿

￿

 

 

 

 

Plug

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Han 7D (metal, gray)

A30

￿

 

 

 

 

 

 

 

 

 

 

 

• Han 8U (instead of Han 7D)

A31

￿

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sealing screws

A40

￿

￿

￿

 

 

 

 

¼-18 NPT, with valve in mat. of process flanges

 

 

 

 

 

 

 

 

Cable sockets for M12 connectors (metal)

A50

￿

￿

￿

 

 

 

 

Rating plate inscription (instead of German)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• English

B11

￿

￿

￿

 

 

 

 

 

 

 

• French

B12

￿

￿

￿

 

 

 

 

• Spanish

B13

￿

￿

￿

 

 

 

 

• Italian

B14

￿

￿

￿

 

 

 

 

English rating plate (calibration certificate)

B21

￿

￿

￿

 

 

 

 

Pressure units in inH2O or psi

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Quality inspection certificate (Factory cali-

C11

￿

￿

￿

 

 

 

 

bration) to IEC 60770-2 1)

 

 

 

 

 

 

 

 

Acceptance test certificate2)

C12

￿

￿

￿

 

 

 

 

To EN 10 204-3.1

 

 

 

 

 

 

 

 

Factory certificate

C14

￿

￿

￿

 

 

 

 

To EN 10 204-2.2

 

 

 

 

 

 

 

 

"Functional Safety (SIL)" certificate

C20

￿

 

 

 

 

 

 

"PROFIsafe" certificate and protocol

C21

 

￿

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Setting of upper limit of output signal to

D05

￿

 

 

 

 

 

 

22.0 mA

 

 

 

 

 

 

 

 

Manufacturer's declaration acc. to NACE

D07

￿

￿

￿

 

 

 

 

(only together with seal diaphragm made of

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Hastelloy and stainless steel)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Type of protection IP68

D12

￿

￿

￿

 

 

 

 

(not together with 7D/

 

 

 

 

 

 

 

 

Han 8U plug, cable gland Pg 13.5)

 

 

 

 

 

 

 

 

Digital indicator alongside the input keys

D27

￿

￿

￿

 

 

 

 

(only together with the devices 7MF4433-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

....2-.A.6 or -.A.7-Z, Y21 or Y22 + Y01)

 

 

 

 

 

 

 

 

Process flange screws made of Monel

D34

 

 

 

 

 

 

 

￿

￿

￿

 

 

 

 

(max. nominal pressure PN20)

 

 

 

 

 

 

 

 

Supplied with oval flange set

D37

￿

￿

￿

 

 

 

 

(2 items), PTFE packings and stainles steel

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

screws in thread of process flanges

 

 

 

 

 

 

 

 

Use in or on zone 1D/2D

E01

 

 

 

 

 

 

 

￿

￿

￿

 

 

 

 

(only together with type of protection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

"Intrinsic safety (EEx ia)")

 

 

 

 

 

 

 

 

Use on zone 0

E02

 

 

 

 

 

 

 

￿

￿

￿

 

 

 

 

(only together with type of protection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

"Intrinsic safety (EEx ia)")

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TÜV approval to AD/TRD

E06

￿

 

 

 

 

 

 

(only together with type of protection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

"Intrinsic safety (EEx ia)")

 

 

 

 

 

 

 

 

Overfilling safety device for flammable

E08

 

 

 

 

 

 

 

￿

￿

￿

 

 

 

 

and non-flammable liquids

 

 

 

 

 

 

 

 

(max. PN 32 (MVWP 464 psi), basic device

 

 

 

 

 

 

 

 

with type of protection "Intrinsic safety

 

 

 

 

 

 

 

 

(EEx ia)", to WHG and VbF, not together with

 

 

 

 

 

 

 

 

measuring cell filling "inert liquid")

 

 

 

 

 

 

 

 

 

 

 

 

 

Selection and Ordering data

Order code

 

 

Further designs

 

HART

PA

FF

Add "-Z" to Order No. and specify Order code.

 

 

 

 

Oxygen application

E10

￿

￿

￿

(max. 120 bar (1740 psi) at 60°C (140 °F) with

 

 

 

 

 

 

 

 

oxygen measurement and inert liquid)

 

 

 

 

Explosion-proof "Intrinsic safety" to

E25

 

 

 

￿

￿

￿

INMETRO (Brazil)

 

 

 

 

(only for transmitter 7MF4...-.....-.B..)

 

 

 

 

 

 

 

 

Explosion-proof "Intrinsic safety" to NEPSI

E55

 

 

 

￿

￿

￿

(China)

 

 

 

 

(only for transmitter 7MF4...-.....-.B..)

 

 

 

 

 

 

 

 

Explosion protection "Explosion-proof" to

E56

 

 

 

￿

￿

￿

NEPSI (China)

 

 

 

 

(only for transmitter 7MF4...-.....-.D..)

 

 

 

 

 

 

 

 

 

Explosion-proof "Zone 2" to NEPSI (China)

E57

￿

￿

￿

(only for transmitter 7MF4...-.....-.E..)

 

 

 

 

 

 

 

 

Interchanging of process connection side

H01

 

 

 

￿

￿

￿

Vent on side for gas measurements

H02

￿

￿

￿

Stainless steel process flanges for vertical

H03

￿

￿

￿

differential pressure lines

 

 

 

 

(not together with K01, K02 and K04)3)

 

 

 

 

Process flange

 

 

 

 

 

 

 

 

• Hastelloy

K01

￿

￿

￿

• Monel

 

 

 

 

K02

￿

￿

￿

• Stainless steel with PVDF insert

K04

￿

￿

￿

max. PN 10 (MWP 145 psi),

 

 

 

 

max. temperature of medium 90 °C (194 °F)

 

 

 

 

For ½-14 NPT inner process connection on

 

 

 

 

 

 

 

 

the side in the middle of the process flange,

 

 

 

 

vent valve not possible

 

 

 

 

￿ = available

 

 

 

 

 

 

 

 

 

1)When the manufacture’s certificate M (calibration certificate) has to be ordered for transmitters with diaphragm seals, it is recommended only to order this certificate exclusively with the diaphragm seals. The measuring accuracy of the total combination is certified here.

2)Whe the acceptance test certificate 3.1 for transmitters with direct-con- nected diaphragm seals is ordered, this certificate must also be ordered with the corresponding seals.

3)Not suitable for connection of remote seal

2/114

Siemens FI 01 · 2009

Page 114