11. Network
11.1 AT*E2CD | Ericsson M2M Cell Description |
|
| |
|
|
|
| |
| Description | Command | Possible Responses | |
|
|
|
|
|
| Request network cell | AT*E2CD=<n> | • | ERROR |
| description |
| • | OK |
|
|
|
| |
| Read the command | AT*E2CD? | • *E2CD: | |
|
|
|
| <n>,<lac>,<ci>,<ta> |
|
|
| • ERROR | |
| Show if the command | AT*E2CD=? | • | *E2CD: (list of |
| is supported |
|
| supported <n>s) |
• ERROR
Controls the presentation of an unsolicited result code E2CD: when <n>=1, or when there is a change in one of the network cell parameters, E2CD: <lac>,<ci>,<ta>.
Read command returns the status of result code presentation and several values, which show the network cell parameters.
Location information <lac>, <ci> and <ta> are returned only when <n>=1 and the ME is registered in the network. To know if the ME is registered use the AT+CREG command. If the ME is not registered in the cellular network an ERROR message is returned.
<n> | Description |
|
|
0 | Disable network location information unsolicited result |
| code. Default value |
1 | Enable network location information unsolicited result |
| code *E2CD: <lac>,<ci>,<ta> |
|
|
|
|
<lac> | Description |
|
|
String type | Two byte location area code in hexadecimal format |
|
|
|
|
<ci> | Description |
|
|
string type | Two byte cell ID in hexadecimal format |
|
|
145
LZT 123 7361 R1A