Standard Horizon GM29 manual 152

Models: GM29

1 266
Download 266 pages 35.21 Kb
Page 152
Image 152

GM29 INTEGRATOR’S MANUAL

<rxqsub>

Description

 

 

4

1.9% < BER < 2.7%

 

 

5

3.8% < BER < 5.4%

 

 

6

7.6% < BER < 11.0%

 

 

7

BER > 15.0%

 

 

 

 

<c1>

Description

 

 

Integer

Path Loss criterion parameter for neighbour cells. The MS

 

calculates this parameter, in idle mode, to decide if the

 

cell is suitable to camp on. After the calculation the

 

criterion is C1 > 0. See GSM 05.08

 

 

<c2>

Description

 

 

Integer

Cell reselection parameter for neighbour cells. This

 

parameter shall optimise the selected cell reselection

 

 

<ta>

Description

 

 

0-63

According to GSM 04.18 V8.6.0, the coding of the timing

 

advance value is the binary representation of the timing

 

advance in bit periods; 1 bit period = 48/13 ìs. <ta> is the

 

integer representation of the timing advance in binary

 

format

64-255

Reserved

 

 

 

 

<tn>

Description

 

 

0-7

Its value indicates the time slot number in a traffic channel

 

 

152