Select the delay to be applied to audio relative to video.

A setting used only to rectify some types of 'lip sync' issues sometimes found with certain endpoints. Leave at default setting, unless advised to alter it by Codian technical support or a reseller.

Controls whether connected endpoints are

This option acts as a unit-wide control over

allowed to use floor and chair control operations.

whether any H.243 floor and chair control

 

operations are permitted. Individual conferences

 

may have their own floor and chair control

 

policies set; however, if this setting is Disabled

 

then no floor or chair control operations will be

 

possible within conferences. Changing this setting

 

will only affect new calls - existing calls will

 

continue with the setting in force when they

 

became active.

 

For more information, refer to H.243 floor and

 

chair control.

 

 

Sets the default action when endpoints call into

This option can make it easier for callers to create

the MCU using an unknown E.164 number; i.e.

ad hoc conferences if Create new conference is

one the does not correspond to any configured

selected. If you do not wish callers to be able to

conference.

create conferences in this way, select one of the

The endpoint will enter the default auto

other options.

 

attendant from which they may join

 

existing conferences or potentially

 

create a new conference (see Using an

 

auto attendant). This behavior is the

 

same as if the endpoint had called the

 

MCU using its IP address rather than an

 

E.164 number.

 

Endpoints are not allowed to call

 

unknown E.164 numbers, and the call

 

will be terminated.

 

A new conference will be created with

 

the E.164 number called as its numeric

 

identifier. The endpoint automatically

 

joins this new conference. This option is

 

not available if the MCU is in port

 

reservation mode.

 

 

 

When enabled, if the MCU is calling out to an

Without this option selected, the caller ID is the

H.323 endpoint, the caller ID that the endpoint

name of the MCU.

will see is the conference name.

 

 

 

Instructs the MCU to request conference

You may wish participants joining a conference

participants dialing into protected conferences

via a gatekeeper not to need to enter a PIN, even

using an E.164 number via an H.323 gatekeeper

for protected conferences. If this is the case, do

to enter a PIN before they may join the

not set this option. If you wish conferences to be

 

 

 

117

Page 119
Image 119
TANDBERG MCU 4500, MSE 8510 manual Chair control, Reservation mode