TANDBERG MSE 8510, MCU 4500 To define a syslog server, simply enter its IP address and then click

Models: MCU 4500 MSE 8510

1 190
Download 190 pages 25.71 Kb
Page 166
Image 166
To define a syslog server, simply enter its IP address and then click

The events that are forwarded to the syslog receiver hosts are controlled by the event log capture filter.

To define a syslog server, simply enter its IP address and then click

. The number of packets

sent to each configured host is displayed next to its IP address.

 

: Each event will have a severity indicator as follows:

0 - Emergency: system is unusable (unused by the MCU)

1 - Alert: action must be taken immediately (unused by the MCU)

2 - Critical: critical conditions (unused by the MCU)

3 - Error: error conditions (used by MCU error events)

4 - Warning: warning conditions (used by MCU warning events)

5 - Notice: normal but significant condition (used by MCU info events)

6 - Informational: informational messages (used by MCU trace events)

7 - Debug: debug-level messages (used by MCU detailed trace events)

If the MCU is being managed by a remote management system, for instance Tandberg TMS, information on that remote system may be shown on this page. In certain circumstances you may need to remove the link between the external system and the MCU using the "Clear" button here.