TANDBERG MCU 4500, MSE 8510 manual Gatekeeper settings Gatekeeper status

Models: MCU 4500 MSE 8510

1 190
Download 190 pages 25.71 Kb
Page 121
Image 121
Gatekeeper settings

To configure gatekeeper settings, go to

.

You can configure the MCU to use a gatekeeper, which can make it easier for end-users to join conferences using directory numbers rather than requiring them to know the IP address or host name of the MCU. The MCU can register up to 100 IDs with the gatekeeper; these IDs comprise conferences' Numeric IDs, the MCU service prefix, and the H.323 ID. If you need to register more than 100 IDs, use a prefix for MCU registrations to route calls to the MCU, rather than registering individual conferences with the gatekeeper. The use of prefixes is described further in the table below.

In this section:

Gatekeeper settings

Gatekeeper status

Refer to this table for assistance configuring the gatekeeper settings. After making any configuration changes, click

.

Enables the MCU to use an H.323 gatekeeper for registration of numeric identifiers for its conferences and/or auto attendants.

When set to Disabled then no gatekeeper registrations are attempted (and existing registrations are torn down), regardless of other gatekeeper or per-conference settings.

When set to Enabled registrations with the gatekeeper are attempted, and the gatekeeper is contacted for incoming and outgoing calls. If the gatekeeper does not respond, calls are still connected if possible. When set to Required registrations with the gatekeeper are attempted but calls are not connected if the gatekeeper cannot be contacted.

Identifies the network address of the gatekeeper

This can be specified either as a host name or as

to which MCU registrations should be made.

an IP address.

 

 

This field will have no effect if H.323 Gatekeeper

 

usage (see above) is set to Disabled.

 

 

The gatekeeper can be either the built-in

 

gatekeeper enabled on the

page (see

 

Displaying the built-in gatekeeper registration

 

list) or an external gatekeeper. To use the built-in

 

gatekeeper enter "127.0.0.1". For an external

 

gatekeeper, enter its host name or IP address.

 

 

Controls how the MCU identifies itself when

Codian recommends that you use the Terminal /

registering with its configured gatekeeper.

gateway option unless you are using a service

 

prefix (in this case, use Gateway). Only use a

 

different option if you are:

 

 

 

 

 

 

119