Displays the IP address of the gatekeeper

The MCU also displays brief status information about its registrations with the configured gatekeeper.

To display a complete list of all IDs that the MCU is attempting to register with the configured H.323 gatekeeper,

click the the H.323 gatekeeper status will indicatelink in the Number of active registrations row of the gatekeeper status table; this takes you to the Active registrations page.

 

 

 

 

 

 

 

Displays the IP address of the gatekeeper

This information might be useful if the gatekeeper

 

currently being used by the MCU.

has been specified with a host name rather than

 

 

with an IP address.

 

 

If the MCU has been unable to reach the

 

 

configured gatekeeper and has instead registered

 

 

with an alternate gatekeeper, the status displayed

 

 

here will be "registered with alternate gatekeeper

 

 

<IP address>".

 

 

 

 

Displays the local IP address and port number that

This information might be useful if the MCU has

 

the MCU has registered with the gatekeeper.

more than one IP address, for instance if both

 

 

Ethernet interfaces are in use.

 

 

 

 

Displays the number of 'alternate' gatekeepers

Where the configured gatekeeper has told the

 

configured on the H.323 gatekeeper. This figure

MCU about any configured 'alternate'

 

comes from the gatekeeper itself; if there are any

gatekeepers and if the MCU loses contact with

 

'alternate' gatekeepers configured, the gatekeeper

the configured gatekeeper, the MCU will attempt

 

tells the MCU their IP addresses.

to register with each of the 'alternates' in turn. If

 

 

none of the 'alternate' gatekeepers responds, the

 

 

MCU will report that the registration has failed.

 

 

If the MCU successfully registers with an

 

 

'alternate' gatekeeper:

 

 

the H.323 gatekeeper status will indicate

 

 

that registration is with an 'alternate'

 

 

the list of 'alternates' received from the

 

 

new gatekeeper will replace the

 

 

previous list

 

 

the MCU will only revert back to the

 

 

original gatekeeper if the 'alternate' fails

 

 

and only if the original gatekeeper is

 

 

configured as an 'alternate' on the

 

 

current gatekeeper's list of 'alternates'

 

 

Note that if the MCU registers with an 'alternate'

 

 

that does not itself supply a list of 'alternates', the

 

 

MCU will retain the original list and if it loses

 

 

contact with the current gatekeeper, each one

 

 

will be attempted from the top again as before.

 

 

 

 

 