Allow/reject incoming and outgoing calls to the

 

 

 

Allow/reject incoming and outgoing calls to the

Disabling this option will prevent calls using SIP

MCU using SIP over UDP or change the port that

over UDP.

is used for this service.

 

 

 

If a port is disabled, this option will be

 

unavailable.

 

You must use the same port number for both

 

Port A and Port B. The number is automatically

 

refreshed for Port B. You cannot change the Port

 

B UDP port numbers and they are always grayed-

 

out; if you want to allow incoming and outgoing

 

SIP (UDP) calls on Port B, ensure that you have

 

the video firewall as an activated feature (refer to

 

Upgrading the firmware) and you have checked

 

the tickbox for SIP (UDP) on Port B.

 

 

 

Enable/disable the receiving of the SNMP

If a port is disabled, this option will be

protocol on this port or change the port that is

unavailable.

used for this service.

 

 

 

You must use the same port number for both

 

Port A and Port B. The number is automatically

 

refreshed for Port B. You cannot change the Port

 

B UDP port numbers and they are always grayed-

 

out; if you want to enable the receiving of the

 

SNMP protocol on Port B, ensure that you have

 

the video firewall as an activated feature (refer to

 

Upgrading the firmware) and you have checked

 

the tickbox for SNMP on Port B.

 

Note that by default SNMP Traps are sent to port

 

UDP port 162 (on the destination network

 

management station); this is configurable. For

 

more information, refer to Configuring SNMP

 

settings.

 

 

 

Enable/disable access to the built-in H.323

If a port is disabled, this option will be

gatekeeper or change the port that is used for the

unavailable.

built-in H.323 gatekeeper.

 

 

 

You must use the same port number for both

 

Port A and Port B. The number is automatically

 

refreshed for Port B. You cannot change the Port

 

B UDP port numbers and they are always grayed-

 

out; if you want to open Port B for the H.323

 

gatekeeper, ensure that you have the video

 

firewall as an activated feature (refer to

 

Upgrading the firmware) and you have checked

 

the tickbox for H.323 gatekeeper on Port B.

 

 

 