4220 Flow Meter

Section 4 Submerged Probe Installation

the mounting ring are not suitable, you must build your own mounting hardware. Figure 4-6shows the dimensions of the probe for your reference when building your own hardware. Figure 4-7shows the probe installed in several primary devices.

Certain flume manufacturers produce flumes with built-in cav- ities for Isco’s submerged probe. Contact the flume manufacturer for details on the special flumes.

Note

Always install the submerged probe pointing toward normal flow at the head-measuring point of the device. The location of the measuring point varies with each device. Refer to Table 4-1or to the Isco Open Channel Flow Measurement Handbook.

Table 4-1 Locating the Head-Measuring Point

Device

Head-Measuring Point

Weirs

Upstream from the weir plate by at least 3 times the

 

maximum head.

 

 

Parshall Flumes

1/3 of the way into the converging section.

Palmer-Bowlus

Upstream from the flume entrance by half the pipe

Flumes

diameter.

 

 

Note

When installing the probe with custom hardware, remember to attach the probe securely to the side or bottom of the flow stream and tie the cable down so that it does not collect debris.

For many primary measuring device installations, the sub- merged probe mounting rings or base sections discussed previ- ously may be used to mount the probe at the appropriate location. In many installations, though, the mounting rings or bases may not be suitable.

Mounting hardware may have to be fabricated locally to allow the level sensor to be mounted at the correct location in the primary device. The only requirements for custom mounting hardware are:

The probe must be securely attached to the side or bottom of the flow stream.

The cable must be tied down and led out of the flow stream in an orderly manner.

The hardware be made from corrosion-resistant materials.

It should be noted that the mounting rings may be used to install the probe in rectangular channels by simply putting right angle bends in them at the appropriate locations. It should be noted

4-11

Page 105
Image 105
Teledyne 4220 installation and operation guide Locating the Head-Measuring Point, Device Head-Measuring Point