4220 Flow Meter

 

 

 

Section 5 Options and Accessories

 

 

 

 

 

mation from the flow meter to a variable analog output current

 

ranging from 4 to 20 milliamperes. When a condition measured

 

by the flow meter is converted into an analog output, 4 mA

 

becomes the 0% or baseline for the condition, while 20 mA

 

becomes the 100% or full-scale of the condition. Teledyne Isco

 

offers two different arrangements for providing the 4-20 mA

 

outputs. One is an external box that converts the signals from

 

the flow meter to a 4-20 mA current loop. The other is an internal

 

circuit board containing from one to three separate analog output

 

circuits on the same board.

 

 

 

 

The 4 to 20 mA current is an industrial standard current loop for

 

process control equipment that must respond to changing condi-

 

tions by varying output rates.

 

 

 

5.3.1 External Analog

The External 4-20 mA Output Interface has its own case and AC

Output Interface

power supply. Commercial power (120 VAC) must be available

 

for this device. Battery operation (12 VDC) is not feasible due to

 

voltage and current demands. It comes with a line cord, con-

 

nectors, and two interconnect cables. One cable has 6-pin M/S

 

connectors on both ends. This cable connects the input of the 4-20

 

mA Output Interface to the flow meter Interrogator connector.

 

The other cable has a three-pin plug on it that connects to the

 

output connector of the 4-20 mA Output Interface. This cable

 

ends in three pigtailed wires you connect to the equipment you

 

want to control with the 4-20 mA Output Interface.

 

 

 

 

Table 5-1 4-20 mA Output Interface Specifications

 

 

 

 

 

 

Power

 

120 VAC

18 Amp.

 

 

 

 

 

Output Connector

 

3-pin male plug

 

 

 

Pin A: + current out

 

 

 

Pin B: – current out

 

 

 

Pin C: not used

 

 

 

 

 

 

 

Output Accuracy:

 

 

 

 

 

At 72° F (22°C)

 

±0.25% of full-scale

 

Full Oper. Range

 

±0.5% of full scale

 

 

 

 

 

Operating Temperature Range

 

0° to 140°F (–18° to 60°C)

 

 

 

 

 

Resolution

 

0.1% of full-scale

 

 

 

 

 

Input Connector

 

6-pin male M/S

 

 

 

Pin B: – pulse input

 

 

 

Pin F: + pulse input

 

 

 

Pins A, C, D, E: NC

 

 

 

 

 

Isolation

 

Output current optically isolated from

 

 

 

flow meter.

 

 

 

 

 

Fusing

 

14 Amp. internal on AC line.

 

 

 

 

 

 

5-5

Page 113
Image 113