4220 Flow Meter
Section 2 Programming
2-52
(TEMPERATURE), (YSI pH), (YSI D.O.), (YSI SALINITY), and
(YSI TEMP) may also appear. Again, as for line A, you can select
another condition to plot on the chart. The flow meter will
request a full-scale value. The full-scale value can be different
from that of line A.
(TEMPERATURE), (YSI pH), (YSI D.O.), (YSI SALINITY), and
(YSI TEMP) may also appear. For line C, you can select yet
another condition to plot on the chart. The flow meter will also
request entry of a full-scale value.
You must have an Isco Rain Gauge or equivalent connected to the
flow meter to measure rainfall. Output is recorded in either
inches or millimeters. Note that there is only one over-range for
rainfall.
2.4.11 Step 9 -
Reports/History
This step lets you set up the flow meter to print periodic reports.
The typical report contains such information as the period of
time covered in the report, maximum and minimum levels, and
when they occurred. You can define two different reports in this
step. For example, this is used to provide weekly and monthly
reports. You can choose the content of the reports by working
through the menus in step 1.
Go to step 9 and the following display will appear:
If you select OFF, the program will advance to the next step, and
there will be no report A generated. If you select YES, the fol-
lowing will appear:
After you select the units of time, this will appear.
DAYS or MONTHS could also appear depending on what you
selected for the previous step. The time selected becomes the
time interval that will be covered in the report. Then the flow
meter will ask you when you want the first report printed:
Then:
INPUT FOR PRINTER LINE C
• NONE • • (LEVEL) • • (FLOW RATE) • • (pH) • • (D. O.) •
PLOT RAINFALL ON CHART?
• NO • • YES •
REPORT GENERATOR A
• ON • • OFF • • (PRINT) •
REPORT A DURATION TO BE IN
• HOURS • • DAYS • • MONTHS •
ENTER REPORT A DURATION
XX HOURS
PRINT REPORT A AT
YR: XXXX MONTH: XX DAY: XX HR: XX MIN: XX
REPORT GENERATOR B
• ON • • OFF • • (PRINT) •