4220 Flow Meter Section 1 Introduction

1.6Technical Specifications

The technical specifications for the 4220 Flow Meter are found in Table 1-2.The anticipated longevity for a roll of paper used in the internal plotter is shown for various chart speeds in Table 1-4.Battery life expectancy is found in Table 1-5.

Table 1-2 Technical Specifications for the 4220 Flow Meter

 

Physical Specifications

Size

16" high 11 12" wide 10 12" deep (40.6 29.2 26.7 cm) (without

 

power source attached).

 

 

Weight

17 lb. 4 oz. (7.7 kg)

 

 

Material

High-impact molded polystyrene structural foam.

 

 

Type

Self-certified NEMA 4X Enclosure.

 

 

Display Type

2-line, 40 character/line alphanumeric dot matrix liquid crystal.

 

 

Power

12 -14 VDC, 16 mA average at 12.5 VDC (Plotter set at 1" per hour).

 

 

Typical Battery Life

7-10 days with plotter at 1" per hour and 4 Ampere-hour Ni-Cad bat-

 

tery.

 

14 days with plotter turned off.

 

 

Operating Temperature

0° to 140°F (–18° to 60°C).

 

 

Storage Temperature

–40° to 158°F (–40° to 70°C).

 

 

 

Additional Power Required

 

for Optional Equipment

Modem

60 mA maximum during operation; 0.1 mA maximum standby.

 

 

High-Low Alarm Relay Box

10 mA standby, typical; 190 mA - both relays operated.

 

 

 

Internal Printer

Chart Speeds

Off, 12, 1, 2, or 4 inches per hour.

Ribbon

19.7 ft. (6 m) black nylon - replaceable.

 

 

Operating Speed

1.5 lines per second at 68° F. (20° C).

 

 

Character Size

0.09" high 0.07" wide (2.4mm 1.7 mm), 12 pitch.

 

 

Printer Recording Span

User-selected from 14 ft. (3.6 cm) to over 30 ft. (9.1 m) with multiple

 

over-ranges.

Chart Resolution

1240 of selected recording span

Display Resolution

0.001 ft. (0.3 mm)

 

 

 

Paper

4.5" wide 65 ft. (11.4 cm 19.8 m) plain white paper, replaceable.

 

 

Printer Reliability

2.5 million lines MCBF (mean cycles before failure).

 

 

Reports Printed

Program selections, interval activity reports, flow meter history.

 

 

Printer Recording Modes

Level, flow rate; includes totalized flow, sampler events, rainfall, tem-

 

perature, velocity, pH (or) D. O. (dissolved oxygen).

 

 

Plotted Linear Data

3 different linear plots can be printed at the same time.

 

 

1-8

Page 22
Image 22
Teledyne installation and operation guide Technical Specifications for the 4220 Flow Meter