TI-83 Plus Communication Link 653
• You attempt a data transfer from a TI-83 Plus to a TI-73 with data
other than real numbers, pics, real lists L1 through L6 or named lists
with q as part of the name.
Although a transmission error does not occur, these two conditions may
prevent successful transmission.
• You try to use Get( with a calculator instead of a CBL 2/CBL or CBR.
• You try to use GetCalc( with a TI-83 instead of a
TI-83 Plus Silver Edition or TI-83 Plus.
Insufficient Memory in Receiving Unit
During transmission, if the receiving unit does not have sufficient
memory to receive an item, the Memory Full menu is displayed on the
receiving unit.
• To skip this item for the current transmission, select 1:Omit.
Transmission resumes with the next item.
• To cancel the transmission and exit receive mode, select 2:Quit.