Tests and Diagnostics

3.3Setting of the hardware configuration

To execute this program, input 1 in the startup menu. Then press Enter to select the (2)- Initial config set. The H/W initial information setting tool consists of four subtests.

Input the number you want to execute and press Enter.

NOTE: Connect USB FDD, when you perform the Repair test program from the CD- ROM. DMI information on the subtest 02 is written in floppy disk.

Subtest 01 Initial configuration

This subtest executes the following items and shows their contents in the display. When an item ends normally, the program proceeds automatically to the next one. When an error is found, the program stops and waits for key input. (After solving the problem, the program executes the item again.)

Setting of the CPU set table

Setting of the micro code

Setting of the EHSS

Inputting and writing of DMI information

When the DMI information is displayed, the following messages appear in order. Input each information. (If you do not replace the PCB, the DMI information should not be changed.)

1.“Enter Model Name?” is displayed. Input the computer’s model name and press Enter. (e.g. DynaBook)

2.“Enter Version Number?” is displayed. Input the computer’s version number and press Enter. (e.g. PC18070C313S)

3.“Enter Serial Number?” is displayed. Input the computer’s serial number and press Enter. (e.g. 12345678)

4.“Enter Model Number?” is displayed. Input the computer’s sales model number and press Enter. (e.g. PP200-AAAAA)

5.“Enter Bundle Number?” is displayed. Input the computer’s PCN/Bundle number and press Enter.

(e.g. PMSREQ3Q34H/S0123456789)

6.“Write data OK (Y/N)?” is displayed. To write the DMI information to the Flash ROM, press Y, and then Enter.

PORTEGE M780 Maintenance Manual (960-809)

[CONFIDENTIAL]

3-15