Toshiba 960-809 manual Smart Check Test

Models: 960-809

1 484
Download 484 pages 342 b
Page 267
Image 267

Tests and Diagnostics

3.34.7.14 SMART CHECK Test

1) Test content

the judgment of the problem existence of HDD is performed using "HDD SMART information."

The check of the number of alternative sectors

The "Raw Value" value of "Reallocated Sector Count" of "SMART ID#5" in the data acquired by "SMART READ ATTRIBUTE DATA" is checked.

If the value becomes 100 or more, it will be considered as an error.

The check of an upper controller log

the latest log reported to the upper controller is checked. and "Error Register" If there is a value, it will judge with an effective log. Next, it tests by reading to LBA by which logging is carried out. "Command=C 8h (Read DMA)" or "25h (Read DMA Ext)" are then used. When a media error is detected by a reading test, it is considered as an error.

■Simple Mode / Detail Mode

The same operation is carried out whichever it chooses.

2) Test screen

a test screen is not displayed.

In the case of PASS

The PASS Count display on the test screen is zoomed in and (OK) is displayed in the Result field on the WinPE T&D screen.

In the case of FAIL

The Error Count on the test screen is zoomed in and (NG) is displayed in the Result field on the WinPE T&D screen.

PORTEGE M780 Maintenance Manual (960-809)

[CONFIDENTIAL]

3-155

Page 267
Image 267
Toshiba 960-809 manual Smart Check Test