Tests and Diagnostics

When this subtest is selected, the following message appears in the display.

The heaven surface establishes in the upper direction Press [Enter] key

NOTE: Be sure to execute the test with the display panel opened.

Set the machine on the flat desk. Then press Enter to detect the data on this setting of machine. The following message appears in the display.

The back establishes in the upper direction

Press [Enter] key

Set the machine against the vertical plane on the flat desk with the back of machine upward. Then press Enter to detect the data on this setting of machine. The following message appears in the display.

The right establishes in the upper direction

Press [Enter] key

Set the machine against the vertical plane on the flat desk with the right side of machine upward. Then press Enter to detect the data on this setting of machine. The following message appears in the display.

The front establishes in the upper direction

Press [Enter] key

Set the machine against the vertical plane on the flat desk with the front of machine upward. Then press Enter to detect the data on this setting of machine. The following message appears in the display.

The left establishes in the upper direction

Press [Enter] key

Set the machine against the vertical plane on the flat desk with the left side of machine upward. Then press Enter to detect the data on this setting of machine.

When there is no defective during the all checks above, the following message appears in the display. Then press Enter and return to the Only One Test menu.

** Setting OK! ** Press [Enter] key

When any trouble in the above setting is found, the following message appears and the test halts. Then press Enter and return to the Only One Test menu.

** Setting ERROR! ** Press [Enter] key

PORTEGE M780 Maintenance Manual (960-809)

[CONFIDENTIAL]

3-55

Page 167
Image 167
Toshiba 960-809 manual Back establishes in the upper direction Press Enter key