Troubleshooting Procedures

Procedure 2 Connector Check and Replacement Check

The Digitizer is connected to the system board as below.

Check 1 If any of the connections are loose, reconnect firmly and repeat Procedure 1. If there is still an error, go to Check 2.

Check 2 The touch screen may be damaged. Replace it with a new one following the instructions in Chapter 4, Replacement Procedures and check the operation. If the problem still exists, perform Check 3.

Check 3 The web camera/digitizer/fingerprint sensor /sw board cable may be damaged. Replace it with a new one following the instructions in Chapter 4, Replacement Procedures. If the problem still exists, perform Check 4.

Check 4 The Digitizer may be damaged. Replace it with a new one following the instructions in Touch screen Troubleshooting and Chapter 4, Replacement Procedures and check the operation. If the problem still exists, perform Check 3.

Check 4 The system board may be damaged. Replace it with a new one following the instructions in Chapter 4, Replacement Procedures.

2-60

[CONFIDENTIAL]

PORTEGE M780 Maintenance Manual (960-809)

Page 102
Image 102
Toshiba 960-809 manual Procedure 2 Connector Check and Replacement Check