Tests and Diagnostics
Subtest 04 | Cross talk & peak shift |
|
| |
| This subtest writes eight types of worst pattern data (listed below) to a | |||
| cylinder, then reads the data while moving from cylinder to cylinder. (Test the | |||
| data interference in the neighbor track) | |||
|
|
|
|
|
|
| Worst pattern data | Cylinder |
|
|
|
|
|
|
|
| ‘B5ADAD’ | 0 cylinder |
|
|
| ‘4A5252’ | 1 cylinder |
|
|
| ‘EB6DB6’ | 2 cylinder |
|
|
| ‘151149’ | 3 cylinder |
|
|
| ’63B63B’ | 4 cylinder |
|
|
| ‘9C49C4’ | 5 cylinder |
|
|
| ‘2DB6DB’ | 6 cylinder |
|
|
| ‘D25114’ | 7 cylinder |
|
Subtest 05 | Partial Read |
|
| |
| This subtest reads 1GB data that is in minimum, middle and maximum | |||
| address of the HDD area. |
|
| |
Subtest 06 | Write specified address |
|
| |
| This subtest writes specified data to a specified cylinder and head on the | |||
| HDD. |
|
| |
Subtest 07 | Read specified address |
|
| |
| This subtest reads data, which has been written to a specified cylinder and | |||
| head on the HDD. |
|
| |
Subtest 08 | Sequential write |
|
| |
| This subtest writes specified | |||
Subtest 09 |
|
| ||
| This subtest writes data to a specified cylinder and head on the HDD, then | |||
| reads the data and compares it to the original data. |
[CONFIDENTIAL] | PORTEGE M780 Maintenance Manual |