Tests and Diagnostics

The n-th offset is computed in the following formulas. X introduces the total number of sectors of HDD.

1

[log2 n]+1

{1+ 2(n − 2

[log

n]

)}

X

([x] The maximum integer that does not exceed x)

 

2

 

2

 

 

 

 

 

 

1000

 

When it becomes (the completion of an HDD test of all the area), it returns to initial offset after that.

Detail Mode

The area (%) which HDD tests are set up. The number of division is determined based on this. When set up to 100%, the Sequential Read test over all the area of HDD is carried out. When set up to 100%, the Sequential Read test over all the area of HDD is carried out.

Subject of examination :

The setting rate of all the HDD area (from a head address to LBA) (%) 1 time of reading size: 64 K bytes

3-126

[CONFIDENTIAL]

PORTEGE M780 Maintenance Manual (960-809)

Page 238
Image 238
Toshiba 960-809 manual 1000