4 Replacement Procedures | 4.31 LCD unit/Touch panel/Digitizer |
4.31 LCD unit/Touch panel/Digitizer
Removing the LCD unit/Touch panel/Digitizer
The following describes the procedure for removing the LCD unit/touch panel/digitizer. (See Figure
1.Turn the display clockwise180 degrees and close the display on the palm rest cover.
2.Peel off the mask seals (9 points) from the LCD mask and remove the following screws securing the LCD mask.
∙ M2.5×6.0B | FLAT HEAD screw | ×9 |
3.Insert your fingers into the slits on both sides and remove the LCD mask while releasing the latches.
M2.5x6.0B FLAT HEAD (with mask seal)
M2.5x6.0B FLAT HEAD (with mask seal)
LCD mask
M2.5x6.0B FLAT HEAD | Slit | |
(with mask seal) | ||
|
Figure 4-51 Removing the LCD mask
[CONFIDENTIAL] | PORTÉGÉ M780 Maintenance Manual |