Tests and Diagnostics
3.35.1.4 List of the error logs recorded on a log file
The list of error logs is shown below.
Section | Log | Explanation |
name |
|
|
|
|
|
[HDD | Read Hdd Create File | It is recorded when a error occurs in |
PHYSICAL] | Error.Address=??? | "drive opening." |
|
|
|
| Read Hdd Set File Pointer | It is recorded when an error occurs in |
| Error.Address=??? | setting processing of a reading |
|
| position. |
|
|
|
| Read Hdd Command | It is recorded when an error occurs by |
| Error.Address=??? | a reading command. |
|
|
|
| Read Hdd Check Size Error | It is recorded when it differs from the |
| Address=??? | reading size as which the read size was |
|
| specified. |
|
|
|
[HDD | HDD TEST:Read Hdd Create | It is recorded when an error occurs in |
LOGICAL] | File Error.Address= ??? | "file opening." |
|
| However, the case of an AccessDenied |
|
| error is excluded. |
|
|
|
| HDDL Error : Access to ??? was | It is recorded when an AccessDenied |
| denied. | error occurs in "file opening." |
|
| Not an error but the test was skipped. |
|
| This log, |
|
| A key becomes "SKIP####" instead of |
|
| "ERROR###." |
|
|
|
| HDDL FileException: | It is recorded when an exception |
|
| occurs during a file operation. |
|
|
|
[MEMORY] | Memory Compar Error | It is recorded when an error occurs in |
| ( Address Test ) | Address Test. |
|
|
|
| Memory Compar Error ( Stack | It is recorded when an error occurs in |
| High/Low Test ) | Stack High/Low Test. |
|
|
|
| Memory Compar Error ( Burst | It is recorded when an error occurs in |
PORTEGE M780 Maintenance Manual | [CONFIDENTIAL] |