Tests and Diagnostics

 

 

Table 3-4

HDC Error register contents

 

 

 

 

 

Bit

Name

 

 

Description

 

 

 

 

7

BBK

 

“0” … Not used

 

(Bad block mark)

 

“1”

… A bad block mark is detected.

6

UNC

 

“0”

… There is no uncorrectable data error.

 

(Uncorrectable)

 

“1”

… Uncorrectable data error has been detected.

 

 

 

 

5

——

 

Not used

 

 

 

 

4

IDN

 

“0” … Not used

 

(Identification)

 

“1”

… There is no ID field in the requested sector.

 

 

 

 

3

——

 

Not used

 

 

 

 

2

ABT

 

“0” … Not used

 

(Abort)

 

“1”

… Illegal command error or command abort.

1

TK0

 

“0” … The hard disk found track 0 during a recalibrate

 

(Track 0)

 

 

command.

 

 

 

“1” … The hard disk could not find track 0 during a

 

 

 

 

recalibrate command.

 

 

 

 

0

——

 

Not used

 

 

 

 

 

PORTEGE M780 Maintenance Manual (960-809)

[CONFIDENTIAL]

3-45

Page 157
Image 157