Toshiba 960-809 manual HDD Logical Test

Models: 960-809

1 484
Download 484 pages 342 b
Page 241
Image 241

Tests and Diagnostics

3.34.7.2HDD Logical Test

1) Test content

This test first verifies that the files which exist on the drive recognized as the built-in HDD are read normally.

During the verification operation, the status update is performed sequentially (display of file names in File Name) and when the verification reaches the last file, it is terminated.

In addition, reading of a file reads 1MB of area from a head. If 1MB of the area reads without a problem and is made, it will be judged as O.K.

Simple Mode

This test mode performs the read test to the first 400 files on the drive.

■Detail Mode

About a setup of 1PASS Count

A Detail test mode specifies the number of times of a test by "1 PASS Count" box of a detailed setting screen. When the number of files of HDD is below a default value at this time, and the reading test of all the PATH files of HDD is completed, it judges with 1PASS. A default preset value tests by reading from a head to 2000 files.

About Folder PASH

Only PATH specified by the folder tree of the Detail setting screen is tested. Only the folder of the root class of each drive can be specified. Moreover, although the file to a root class is not displayed on a folder tree, it tests. Moreover, although the file to a root class is not displayed on a folder tree, it tests. It will be referred to as "1PASS" if the reading test of all the specified PATH files is completed.

2) Test screen

File Name: Displays the name of the file being verified with full path.

PORTEGE M780 Maintenance Manual (960-809)

[CONFIDENTIAL]

3-129

Page 241
Image 241
Toshiba 960-809 manual HDD Logical Test