SERVICE PROGRAM TABLES April, 2007

5-26

1106
Fusing Temp Disp Fusing Lamp Control Method/Temperature Display
These SP codes control the temperature control of the hot roller and display the
temperatures of the hot roller, pressure roller, heating roller, and heating roller
lamps.
001
Temp Ctrl On/Off Hot roller fusing lamp control switch
0: OFF, 1: PID
002
Phase Ctrl On/Off Hot roller phase control
0:OFF 1:ON
003
Htg Roll Ctr Temp Displays the temperature in centigrade of the fus ing lamp
(center) in the heating roller. Range: 0 to 230
004
Htg Roll End Temp Displays the temperature in centigrade of the fusing lamp
(ends) in the heating roller. Range: 0 to 230
005
Press Roll Temp Displays the temperature in centigrade of the pressure
roller. Range: 0 to 230
006
Hot Roll Temp Displays the temperature in centigrade of the hot roller.
Range: 0 to 230
Mode Shift Setting Mode Shift Setting 1107
001
Low Temp SW The calculated value for the specified temperatures when
the readings of the environmental sensors are low.
[0~20/1 deg.]
002
High Temp SW The calculated value for the specified temperatures when
the readings of the environmental sensors are high.
[-20~0/1 deg.]
003
Pres Roll Reload * This function in not used in this model.
004
Idle Temp On/Off The hot roller temperature that det er mines whether the
fusing unit rollers are rotated freely during warmup.
[80~200/1 deg.]
005
Idle Time:Extend The length of time the fusing/exit motor remains on after
the fusing unit has reached the warmup temperature.
[0~10/1 min.]
006
Feed Norm Temp De termines whether fusing exit motor remains before
feeding plain paper after warmup temperature for the
heating roller has been reached.
0: No 1: Yes
007
Press Temp:Norm The temperature calculated for the specified temperature
when the fusing/exit motor starts to rotate when plain
paper starts to feed.
[0~20/1 deg.]
008
Press Time:Norm The time calculated to be added to the rotation time of the
fusing/exit motor at the start of plain paper feed, based on
the temperature specified temperature.
[0~60/1 deg.]
009
Fuse Exit M Cycles The cycles of the fusing/exit motor at standby.
[10~240/1 min. ]
010
Fuse Exit M Rot The time the fusing exit motor rotates at standby.
[0~1/1 sec.]