P-2602H(W)(L)-DxA Series User’s Guide

21.6.2 SNMP Traps

The ZyXEL Device will send traps to the SNMP manager when any one of the following events occurs:

Table 108

SNMP Traps

 

 

 

 

TRAP #

TRAP NAME

DESCRIPTION

 

 

 

0

coldStart (defined in RFC-1215)

A trap is sent after booting (power on).

 

 

 

1

warmStart (defined in RFC-1215)

A trap is sent after booting (software reboot).

 

 

 

4

authenticationFailure (defined in

A trap is sent to the manager when receiving any

 

RFC-1215)

SNMP get or set requirements with the wrong

 

 

community (password).

6

whyReboot (defined in ZYXEL-

A trap is sent with the reason of restart before

 

MIB)

rebooting when the system is going to restart (warm

 

 

start).

6a

For intentional reboot:

A trap is sent with the message "System reboot by

 

 

user!" if reboot is done intentionally, (for example,

 

 

download new files, CI command "sys reboot", etc.).

6b

For fatal error:

A trap is sent with the message of the fatal code if the

 

 

system reboots because of fatal errors.

21.6.3 Configuring SNMP

To change your ZyXEL Device’s SNMP settings, click Advanced > Remote MGMT > SNMP. The screen appears as shown.

Chapter 21 Remote Management Configuration

273

Page 273
Image 273
ZyXEL Communications P-2602 manual Snmp Traps, Configuring Snmp, Remote Management Configuration 273