Chapter 32 Introducing the Commands

Table 85 vdsl-profile Commands (continued)

COMMAND

 

DESCRIPTION

P

 

 

us <12>

Sets a rate adaptive mode for the

13

 

 

 

upstream traffic

 

 

 

 

1: Manual

 

 

 

 

2: AdaptAtInit

 

 

 

 

 

 

 

rateratio

ds <0..100>

Specify the downstream data rate

13

 

 

 

allocated for the fast and slow

 

 

 

 

channels.

 

 

 

 

0: slow channel

 

 

 

 

100: fast channel

 

 

 

 

 

 

 

 

us <0..100>

Specify the upstream data rate

13

 

 

 

allocated for the fast and slow

 

 

 

 

channels.

 

 

 

 

0: slow channel

 

 

 

 

100: fast channel

 

 

 

 

 

 

 

snr

dsmax <0..127>

Sets the maximum downstream

13

 

 

 

SNR (Signal to Noise Ratio).

 

 

 

dsmin <0..127>

Sets the minimum downstream

13

 

 

 

SNR (Signal to Noise Ratio).

 

 

 

dstarget

Sets the target downstream SNR

13

 

 

<0..127>

(Signal to Noise Ratio).

 

 

 

usmax <0..127>

Sets the maximum upstream

13

 

 

 

SNR (Signal to Noise Ratio).

 

 

 

usmin <0..127>

Sets the minimum upstream SNR

13

 

 

 

(Signal to Noise Ratio).

 

 

 

ustarget

Sets the target upstream SNR

13

 

 

<0..127>

(Signal to Noise Ratio).

 

 

targetslowburst

ds <0..1275>

Sets the target burst rate for the

13

 

 

 

downstream slow channel.

 

 

 

us <0..1275>

Sets the target burst rate for the

13

 

 

 

upstream slow channel.

 

32.11.8 vlan Commands

The following table lists the vlan commands in configuration mode.

Table 86 vlan Commands

COMMAND

 

DESCRIPTION

P

vlan <1-4094>

 

 

Creates a new VLAN group.

13

 

exit

 

Leaves the VLAN configuration mode.

13

 

fixed <port-

 

Specifies the port(s) to be a permanent

13

 

list>

 

member of this VLAN group.

 

 

forbidden

 

Specifies the port(s) you want to prohibit from

13

 

<port-list>

 

joining this VLAN group.

 

 

help

 

Displays a list of available VLAN commands.

13

 

inactive

 

Disables the specified VLAN.

13

 

ip address

<ip-address>

Sets the IP address and subnet mask of the

13

 

 

<mask>

switch in the specified VLAN for packet

 

 

 

 

loopback test.

 

240

 