Chapter 6 Basic Setting

The following table describes the labels in this screen.

Table 12 IP Setup

LABEL

DESCRIPTION

Domain Name

Enter the IP address of the domain name server in dotted decimal notation, for

Server

example 192.168.1.20.

 

 

Default

Select which traffic flow (In-Bandor Out-of-band) the switch is to use to send

Management

packets with an unknown source or that originated from the switch itself (such as

 

SNMP traps).

 

Select Out-of-bandto have the switch send the packets to the out-of-band

 

management port. This means that device(s) connected to the other port(s) do not

 

receive these packets.

 

Select In-Bandto have the switch send the packets to all ports except the out-of-

 

band management port. This means that device(s) connected to out-of-band

 

management port do not receive these packets.

 

 

In-band Management IP Address

 

 

DHCP Client

Select this option if you have a DHCP server that can assign the switch an IP

 

address and subnet mask, a default gateway IP address and a domain name server

 

IP address.

 

 

Static IP

Select this option if you don't have a DHCP server or if you wish to assign static IP

Address

address information to the switch. You need to fill in the following fields when you

 

select this option.

 

 

IP Address

Enter the IP address of your switch in dotted decimal notation for example

 

192.168.1.1.

 

 

IP Subnet

Enter the IP subnet mask of your switch in dotted decimal notation for example

Mask

255.255.255.0.

 

 

Default

Enter the IP address of the default outgoing gateway in dotted decimal notation, for

Gateway

example 192.168.1.254

 

 

VID

Enter the VLAN identification number associated with the switch IP address. This is

 

the VLAN ID of the CPU and is used for management only. The default is "1". All

 

ports, by default, are fixed members of this "management VLAN" in order to

 

manage the device from any port. If a port is not a member of this VLAN, then users

 

on that port cannot access the device. To access the switch make sure the port that

 

you are connected to is a member of Management VLAN.

 

 

Out-of-band Management IP Address

 

 

IP Address

Enter the IP address of your switch in dotted decimal notation for example

 

192.168.0.1.

 

 

IP Subnet Mask

Enter the IP subnet mask of your switch in dotted decimal notation for example

 

255.255.255.0.

 

 

Apply

Click Apply to save the settings.

 

 

Cancel

Click Cancel to reset the fields to your previous configuration.

 

 

In-band IP Addresses

You can create up to 128 IP addresses, which are used to access and manage the switch from the ports belonging to the pre-defined VLAN(s). You must configure a VLAN first.

IP Address

Enter the IP address for managing the switch by the members of the VLAN

 

specified in the VID field below.

 

 

IP Subnet Mask

Enter the IP subnet mask in dotted decimal notation.

 

 

VID

Type the VLAN group identification number.

 

 

Default Gateway

Enter the IP address of the default outgoing gateway in dotted decimal notation.

 

 

 