1 Getting Started Tutorial
Button |
| Function when pressed for less than 1 second |
| Function when pressed for more than 1 second | ||||||||
|
|
|
|
|
|
|
|
|
| |||
4 |
|
| scrolls through the measuring function(s) at a |
|
|
| enters Log Review mode. Press | to | ||||
|
| particular rotary switch position. |
| switch to manual or interval logging data. Press |
| |||||||
|
|
|
|
|
| or |
|
| to view first or last logged data respectively. | |||
|
|
|
|
|
|
|
|
| or | to scroll up or down logged data. | ||
|
|
|
|
|
| Press | ||||||
|
|
|
|
|
| Press |
|
| for more than 1 second to exit mode. | |||
|
|
|
|
|
|
|
|
|
| |||
5 |
|
| scrolls through available measuring ranges |
|
|
| sets to Auto Range mode. |
| ||||
|
| (except when rotary switch is set at TEMP or at Hz [for |
|
|
|
|
|
|
| |||
|
| U1252A] position) [2]. |
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| ||||
6 |
|
| scrolls through available |
|
|
| exits Hold, Null, Dynamic Recording, 1 ms | |||||
|
| displays (except when rotary switch is set at TEMP, Hz | Peak Hold and dual display modes. |
| ||||||||
|
| or | [for U1252A] position, or when meter is in |
|
|
|
|
|
|
| ||
|
| 1 ms peak hold or dynamic recording mode) [3]. |
|
|
|
|
|
|
| |||
7 |
|
| enters Frequency Test mode for current or |
|
|
| enters logging mode. In manual data logging, | |||||
|
| voltage measurements. Press | to scroll through | press |
|
|
| to log data manually into memory. In | ||||
|
| frequency (Hz), duty cycle (%) and pulse width (ms) |
|
|
| |||||||
|
| automatic data logging, data logs automatically [1]. | ||||||||||
|
| functions. In duty cycle (%) and pulse width (ms) | Press |
|
| for more than 1 second to exit auto data | ||||||
|
| tests, press | to switch to positive or negative | logging mode. |
|
| ||||||
|
| pulse. |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
Notes for keypad descriptions and functions:
1See Table
2 | When rotary switch is at TEMP, press | to switch to ºC or ºF display. When rotary switch is at Hz, press | to | ||||
| switch to division of signal frequency by 1 or 100. |
|
|
| |||
3 | When rotary switch is at TEMP, ETC is ON by default. You may press | to disable ETC (Environment Temperature | |||||
| Compensation), |
| will appear on display. For pulse and duty cycle measurement, press | to switch trigger slope | |||
|
| ||||||
| to positive or negative. When meter is in peak or | to restart 1 ms peak hold or |
| ||||
| dynamic recording mode. |
|
|
|
| ||
|
|
|
|
|
|
|
|
10 | Agilent U1251A/U1252A User’s and Service Guide |