Maintenance 5

6Gently remove the defective fuse by prying one end of the fuse loose and removing it out of the fuse bracket.

7Replace with a new fuse of the same size and rating. Make sure the new fuse is centered in the fuse holder.

8Ensure that the rotary switch on the top case and the circuit board switch stay on the OFF position.

9Then re- fasten the circuit board and the bottom cover.

10Refer to the table below for the part number, rate, and size of the fuses.

Table 5-4Fuse specifications

Fuse

Agilent part number

Rating

Size

Type

1

2110-1400

440 mA/1000 V

10 mm × 35 mm

Fast blow fuse

 

 

 

 

2

2110-1402

11 A/1000 V

10 mm × 38 mm

 

 

 

 

 

 

Fuse 1

Fuse 2

Figure 5-7Fuse replacement

Agilent U1251A/U1252A User’s and Service Guide

107

Page 127
Image 127
Agilent Technologies U1251A manual 4Fuse specifications, Fuse Agilent part number Rating Size Type