Drive Enclosure

5.6.5DC OUTPUT PCM

Output Parameter

3.3 VDC Output

5 VDC Output

12 VDC Output

Normal Voltage

3.3 VDC

5.10 VDC

12.10 VDC

Full Load

5.0A

55.0A

120.0A

Peak Load for 1 Second

5.0A

65.0A

130.0A

Minimum Load (A)

0.0A

0.0A

0.0A

5.6.6PCM Safety and EMC Compliance

Safety Compliance

UL 60950

 

IEC 60950

 

EN 60950

EMC Compliance

CFR47 Part 15B Class A

 

EN55022

 

EN55024

5.6.7 Power Cord

 

(minimum requirements)

 

Cord Type

SV or SVT, 18 AWG minimum, 3 conductor

Plug

250V, 10A

Socket

IEC 320 C-14, 250V, 15A

Note Power cord is not included in the standard drive enclosure package.

5.7 Environment

The enclosure and all of its sub-components are compliant to the European Union RoHS (Restriction of Hazardous Substances) Directive (Directive 2002/95/EC) with no exceptions or exemptions.

007-5510-002

107

Page 121
Image 121
APC 15000 RAID manual Environment, PCM Safety and EMC Compliance, Power Cord