Controller Management
3.8Other Utilities
3.8.1APC UPS SNMP Trap Monitor
APC_UPS displays the status of the APC UPS SNMP trap monitor (Figure
15000 [1]: apc_ups
APC UPS SNMP trap monitor is off.
No APC UPS faults detected via SNMP trap.
Figure 3–61 APC UPS SNMP Trap Monitor Status
APC_UPS CLEAR_FAULTS will delete all pending APC UPS faults from the fault list. All APC UPS events that disabled writeback caching will be cleared.
3.8.2API Server Connections
The API command displays the current status of the API connections (Figure
15000 [1]: api
API Server connections are currently
Figure 3–62 Displaying Status of API Connections
API DISABLE temporarily enables/disables the establishment of connections to the API server. When disabled, users at remote locations will be unable to establish a new API connection until an
API ENABLE command is issued. This command only provides control over API connections during the current power cycle.
API STATS displays the collected statistics on API connections (Figure
Figure 3–63 API Server Connection Statistics
3.8.3Changing Baud Rate for the CLI Interface
The CONSOLE command displays the current serial console setting (Figure
81 |