Introduction
Table | LED Indicators |
|
| |
|
|
|
|
|
|
| Status Indicator | Led Activity | Explanation |
|
| Disk | Solid Green | All related disk enclosures are operating |
|
|
|
| normally |
|
|
|
|
|
|
|
| Solid Amber | There is a problem with 1 or more of the disk |
|
|
|
| enclosures |
|
|
|
|
|
|
| Temp Status | Solid Green | All temp sensors operating normally |
|
|
|
|
|
|
|
| Solid Amber | At least 1 temp sensor has reported over- |
|
|
|
| temperature conditions |
|
|
|
|
|
|
|
| Solid Red | 2 or more temp sensors has reported over- |
|
|
|
| temperature condition |
|
|
|
|
|
|
| DC | Solid Green | Operating normally |
|
|
|
|
|
|
|
| Solid Amber | |
|
|
|
|
|
|
|
| Solid Red | Critical power supply fault |
|
|
|
|
|
|
| Fan Status | Solid Green | Operating normally |
|
|
|
|
|
|
|
| Flashing Green | System monitoring activity |
|
|
|
|
|
|
|
| Flashing Amber | 1 fan has failed and needs to be replaced |
|
|
|
|
|
|
|
| Solid Red | 2 or more fans have failed or are undetected and |
|
|
|
| the system will shutdown in 30 seconds |
|
|
|
|
|
|
| AC Fail | Solid Green | Operating normally |
|
|
|
|
|
|
|
| Solid Red | Power input to supply not present. AC failure |
|
|
|
|
|
|
| FC | Solid | Physical connection has been made. |
|
|
|
|
|
|
|
| Flashing | Data is being transferred. |
|
|
|
|
|
1.2.3Uninterruptible Power Supply (UPS)
Using an Uninterruptible Power Supply (UPS) with the controller is highly recommended. The UPS can guarantee power to the system in the event of a power failure for a short time, which will allow the system to power down properly.
SGI offers two types of UPS: basic and redundant. The basic UPS is
NOTE : The UPS should be installed by a licensed electrician. Contact SGI to obtain circuit and power requirements.
9 |