APC 15000 RAID manual Setting the System’s Date and Time, System Shutdown, System Date

Models: 15000 RAID

1 152
Download 152 pages 41.45 Kb
Page 60
Image 60

RESTART DUAL restarts both units.

RESTART KILL stops a timed restart that is in progress.

3.2.5.2System Shutdown

SHUTDOWN shuts down the controller unit.

If you need to power down the controller, use SHUTDOWN prior to shutting off power. This will cause the controller to flush its cache, abort all format and rebuild operations, and proceed with an orderly shutdown.

All hosts actively using the controller should be safely shutdown and all users logged out before using this command. The controller will halt all I/O requests and save the data to the disks.

NOTE : Use SHUTDOWN whenever you power down the controller for maintenance. SHUTDOWN flushes any data left in the cache and prepares the controller for an orderly shutdown. For couplet controller configuration, issue SHUTDOWN to both controllers.

To perform a hard restart of the unit by cycling the power, use: a value between 1 and 1023 seconds before the unit powers up default is 15 seconds.

SHUTDOWN RESTART=X, where X is again. If the number is not specified, the

NOTE : If SHUTDOWN RESTART is used in conjunction with the DUAL parameter, the restart will only affect unit where it was issued on and not both.

SHUTDOWN DELAY=X delays a shutdown of a unit between 0 and 255 minutes (where x is minutes delayed).

SHUTDOWN DUAL shutdowns both units.

SHUTDOWN KILL stops a timed shutdown that is in progress.

3.2.6Setting the System’s Date and Time

Valid date settings are between years 2000 and 2104. In dual mode, settings should always be done on Unit 1. Changes will automatically be applied to both units. Settings are automatically adjusted for leap years.

3.2.6.1System Date

DATE displays the current system date.

You can also change the system date. At the prompt, type:

date mm dd yyyy <Enter>

where mm represents the two digit value for month, dd represents the two digit value for day, and yyyy represents the four digit value for year.

For example, to change the date to March 14, 2009, type:

date 03 14 2009<Enter>.

46

007-5510-002

Page 60
Image 60
APC 15000 RAID manual Setting the System’s Date and Time, System Shutdown, System Date