Chapter 46 Configuring Online Diagnostics

Configuring Online Diagnostics

Configuring Online Diagnostics

You must configure the failure threshold and the interval between tests before enabling diagnostic monitoring.

This section has this information:

Scheduling Online Diagnostics, page 46-2

Configuring Health-Monitoring Diagnostics, page 46-3

Scheduling Online Diagnostics

You can schedule online diagnostics to run at a designated time of day or on a daily, weekly, or monthly basis for a switch. Use the no form of this command to remove the scheduling.

Use this global configuration command to schedule online diagnostics:

Command

Purpose

 

 

diagnostic schedule switch

Schedule on-demand diagnostic tests for a specific day and time.

number test {name test-id

The switch number keyword is supported only on Catalyst 3750-E switches. The range

test-id-range all basic

is from 1 to 9.

non-disruptive} {daily hh:mm

When specifying the tests to be scheduled, use these options:

on mm dd yyyy hh:mm weekly

day-of-week hh:mm}

name—Name of the test that appears in the show diagnostic content command

 

 

output.

 

test-id—ID number of the test that appears in the show diagnostic content command

 

output.

 

test-id-range—ID numbers of the tests that appear in the show diagnostic content

 

command output.

 

all—All of the diagnostic tests.

 

basic—Basic on-demand diagnostic tests.

 

non-disruptive—Nondisruptive health-monitoring tests.

 

You can schedule the tests as follows:

 

Daily—Use the daily hh:mm parameter.

 

Specific day and time—Use the on mm dd yyyy hh:mm parameter.

 

Weekly—Use the weekly day-of-week hh:mm parameter.

 

For detailed information about this command, see the command reference for this release.

 

 

Use the no diagnostic schedule switch number test {name test-idtest-id-rangeall basic non-disruptive} {daily hh:mm on mm dd yyyy hh:mm weekly day-of-week hh:mm} global configuration command to remove the scheduled tests.

This example shows how to schedule diagnostic testing for a specific day and time on a Catalyst 3560-E switch:

Switch(config)# diagnostic schedule test TestPortAsicCam on december 3 2006 22:25