Cisco Systems 3750E manual Wattage, 11-28

Models: 3750E

1 1236
Download 1236 pages 40.08 Kb
Page 324
Image 324

Chapter 11 Configuring Interface Characteristics

Configuring Ethernet Interfaces

Caution You should carefully plan your switch power budget, enable the power monitoring feature, and make certain not to oversubscribe the power supply.

Note When you manually configure the power budget, you must also consider the power loss over the cable between the switch and the powered device.

When you enter the power inline consumption default wattage or the no power inline consumption default command, this caution message appears:

%CAUTION: Interface Gi1/0/1: Misconfiguring the 'power inline consumption/allocation' command may cause damage to the switch and void your warranty. Take precaution not to oversubscribe the power supply.

It is recommended to enable power policing if the switch supports it. Refer to documentation.

For more information about the IEEE power classifications, see the “Power over Ethernet Ports” section on page 11-6.

Beginning in privileged EXEC mode, follow these steps to configure the amount of power budgeted to a powered device connected to each PoE port on a switch:

 

Command

Purpose

Step 1

 

 

configure terminal

Enter global configuration mode.

Step 2

 

 

no cdp run

(Optional) Disable CDP.

Step 3

 

 

power inline consumption default

Configure the power consumption of powered devices connected to each

 

wattage

the PoE port on the switch. The range for each device is 4000 to

 

 

15400 mW. The default is 15400 mW.

Step 4

 

 

end

Return to privileged EXEC mode.

Step 5

 

 

show power inline consumption

Display the power consumption status.

 

default

 

Step 6

 

 

copy running-config startup-config

(Optional) Save your entries in the configuration file.

 

 

 

To return to the default setting, use the no power inline consumption default global configuration command.

Beginning in privileged EXEC mode, follow these steps to configure amount of power budgeted to a powered device connected to a specific PoE port:

 

 

Command

Purpose

 

 

 

 

 

 

 

Step 1

configure terminal

Enter global configuration mode.

 

 

 

 

 

 

 

Step 2

no cdp run

(Optional) Disable CDP.

 

 

 

 

 

 

 

Step 3

interface interface-id

Specify the physical port to be configured, and enter interface

 

 

 

 

 

configuration mode.

 

 

 

 

 

 

 

Step 4

power inline consumption default

Configure the power consumption of a powered device connected to a

 

 

 

wattage

PoE port on the switch. The range for each device is 4000 to 15400 mW.

 

 

 

 

 

The default is 15400 mW.

 

 

 

 

 

 

 

 

 

 

Catalyst 3750-E and 3560-E Switch Software Configuration Guide

 

 

 

 

 

 

11-28

 

 

OL-9775-02

 

 

 

 

 

Page 324