Chapter 11 Configuring Interface Characteristics

Configuring the Power Supplies

 

Command

Purpose

Step 3

 

 

power rps switch-number priority priority

Set the priority of the RPS 2300 port. The range is

 

 

from 1 to 6, where 1 is the highest priority and 6 is

 

 

the lowest priority.

 

 

The default port priority is 6.

Step 4

 

 

show env rps

Verify your settings.

Step 5

 

 

copy running-config startup-config

(Optional) Save your entries in the configuration

 

 

file.

 

 

 

To return to the RPS 2300 default settings, use these commands:

To return to the default name setting (no name is configured), use the power rps switch-numberport rps-port-idname ““ user EXEC command with no space between the quotation marks.

To return to the default port mode, use the power rps switch-numberport rps-port-idactive command.

To return to the default port priority, use the power rps switch-numberport rps-port-idpriority command.

For more information about using the power rps user EXEC command, see the command reference for this release.

Configuring the Power Supplies

You can enter the power supply user EXEC command to configure and manage the internal power supply on the switch.

Note The Catalyst 3750 and 3560 switches do not support the power supply command.

Beginning in user EXEC mode, follow these steps to configure and manage the power supply:

 

 

Command

 

Purpose

 

 

Step 1

 

 

 

 

 

power supply switch-number{off on}

 

Set the switch power supply to off or on by using

 

 

 

 

one of these keywords:

 

 

 

 

off—Set the power supply off.

 

 

 

 

on—Set the power supply on.

 

 

 

 

The switch-numberis supported only on

 

 

 

 

Catalyst 3750-E switches.

 

 

 

 

By default, the switch power supply is on.

 

Step 2

 

 

 

 

 

show env power

 

Verify your settings.

 

Step 3

 

 

 

 

 

copy running-config startup-config

 

(Optional) Save your entries in the configuration

 

 

 

 

file.

 

 

 

 

 

 

 

The switch does not support the no power supply user EXEC command. To return to the default setting,

 

 

use the power supply switch-numberon command.

 

 

 

Catalyst 3750-E and 3560-E Switch Software Configuration Guide

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OL-9775-02

 

 

 

11-37

 

 

 

 

 

 

 