Cisco Systems 3750E manual Configuring Obfl, 45-27

Models: 3750E

1 1236
Download 1236 pages 40.08 Kb
Page 1119
Image 1119

Chapter 45 Troubleshooting

Using On-Board Failure Logging

Power over Ethernet (PoE)—Record of the power consumption of PoE ports on a standalone switch or a stack member

Temperature—Temperature of a standalone switch or a switch stack member

Uptime data—Time when a standalone switch or stack member starts, the reason the switch restarts, and the length of time the switch has been running since it last restarted

Voltage—System voltages of a standalone switch or a stack member

You should manually set the system clock or configure it by using Network Time Protocol (NTP).

When the switch is running, you can retrieve the OBFL data by using the show logging onboard privileged EXEC commands. If the switch fails, contact your Cisco technical support representative to find out how to retrieve the data.

Note OBFL is supported only on Catalyst 3750-E and 3560-E switches. It is not supported on Catalyst 3750 and 3560 switches.

Configuring OBFL

To enable OBFL, use the hw-module module [switch-number]logging onboard [message level level] global configuration command. On Catalyst 3750-E switches, the range for switch-numberis from 1 to 9. On Catalyst 3560-E switches, the switch number is always 1. Use the message level level parameter to specify the severity of the hardware-related messages that the switch generates and stores in the flash memory.

Caution We recommend that you do not disable OBFL and that you do not remove the data stored in the flash memory.

To disable OBFL, use the no hw-module module [switch-number]logging onboard [message level] global configuration command.

To clear all the OBFL data in the flash memory except for the uptime and CLI command information, use the clear logging onboard privileged EXEC command.

In a switch stack, you can enable OBFL on a standalone switch or on all stack members by using the hw-module module logging onboard [message level level] global configuration command.

In a switch stack, if you enter the hw-module module [switch-number] logging onboard command on a stack member that does not support OBFL, such as a Catalyst 3750 switch, a message appears with that information. If a Catalyst 3750 switch is a stack master in a mixed stack of Catalyst 3750-E and 3750 switches and you enter an OBFL command on the Catalyst 3750 switch, the command does not take effect on the stack master, but the stack master sends the OBFL configuration information to the stack members.

For more information about the commands in this section, see the command reference for this release.

 

 

Catalyst 3750-E and 3560-E Switch Software Configuration Guide

 

 

 

 

 

 

OL-9775-02

 

 

45-27

 

 

 

 

 