Chapter 5 Managing Switch Stacks

Understanding Switch Stacks

*Mar 11 20:36:15.038:%IMAGEMGR-6-AUTO_COPY_SW:extracting c3750e-universal-mz.122-0.0.313.SE/c3750e-universal-mz.122-35.SE2 (4945851 bytes) *Mar 11 20:36:15.038:%IMAGEMGR-6-AUTO_COPY_SW:extracting c3750e-universal-mz.122-35.SE2/info (450 bytes)

*Mar 11 20:36:15.038:%IMAGEMGR-6-AUTO_COPY_SW:extracting info (104 bytes) *Mar 11 20:36:15.038:%IMAGEMGR-6-AUTO_COPY_SW:

*Mar 11 20:36:15.038:%IMAGEMGR-6-AUTO_COPY_SW:Installing (renaming):`flash1:update/c3750e-universal-mz.122-0.0.313.SE2' -> *Mar 11 20:36:15.038:%IMAGEMGR-6-AUTO_COPY_SW: `flash1:cc3750e-universal-mz.122-35.SE2'

*Mar 11 20:36:15.038:%IMAGEMGR-6-AUTO_COPY_SW:New software image installed in flash1:c3750e-i5-mz.122-35.SE2

*Mar 11 20:36:15.038:%IMAGEMGR-6-AUTO_COPY_SW: *Mar 11 20:36:15.038:%IMAGEMGR-6-AUTO_COPY_SW:

*Mar 11 20:36:15.038:%IMAGEMGR-6-AUTO_COPY_SW:Removing old image:flash1:c3750e-universal-mz.122-35.SE2

*Mar 11 20:36:15.038:%IMAGEMGR-6-AUTO_COPY_SW:

*Mar 11 20:36:15.038:%IMAGEMGR-6-AUTO_COPY_SW:All software images installed.

*Mar 11 20:36:15.038:%IMAGEMGR-6-AUTO_COPY_SW:Requested system reload in progress...

*Mar 11 20:36:15.038:%IMAGEMGR-6-AUTO_COPY_SW:Software successfully copied to *Mar 11 20:36:15.038:%IMAGEMGR-6-AUTO_COPY_SW:system(s) 1

*Mar 11 20:36:15.038:%IMAGEMGR-6-AUTO_COPY_SW:Done copying software *Mar 11 20:36:15.038:%IMAGEMGR-6-AUTO_COPY_SW:Reloading system(s) 1

This example shows that the switch stack detected a new switch that is running a different minor version number than the switch stack. Auto-copy starts but cannot find software in the switch stack to copy to the VM-mode switch to make it compatible with the switch stack. The auto-advise process starts and recommends that you download a tar file from the network to the switch in VM mode:

*Mar 1 00:01:11.319:%STACKMGR-6-STACK_LINK_CHANGE:Stack Port 2 Switch 2 has changed to state UP

*Mar 1 00:01:15.547:%STACKMGR-6-SWITCH_ADDED_VM:Switch 1 has been ADDED to the stack

(VERSION_MISMATCH) stack_2#

*Mar 1 00:03:15.554:%IMAGEMGR-6-AUTO_COPY_SW_INITIATED:Auto-copy-software process initiated for switch number(s) 1

*Mar 1 00:03:15.554:%IMAGEMGR-6-AUTO_COPY_SW:

*Mar 1 00:03:15.554:%IMAGEMGR-6-AUTO_COPY_SW:Searching for stack member to act *Mar 1 00:03:15.554:%IMAGEMGR-6-AUTO_COPY_SW:as software donor...

*Mar 1 00:03:15.554:%IMAGEMGR-6-AUTO_COPY_SW:Software was not copied

*Mar 1 00:03:15.562:%IMAGEMGR-6-AUTO_ADVISE_SW_INITIATED:Auto-advise-software process initiated for switch number(s) 1

*Mar 1 00:04:22.537:%IMAGEMGR-6-AUTO_ADVISE_SW: *Mar 1 00:04:22.537:%IMAGEMGR-6-AUTO_ADVISE_SW:

*Mar 1 00:04:22.537:%IMAGEMGR-6-AUTO_ADVISE_SW:Systems with incompatible software *Mar 1 00:04:22.537:%IMAGEMGR-6-AUTO_ADVISE_SW:have been added to the stack. The *Mar 1 00:04:22.537:%IMAGEMGR-6-AUTO_ADVISE_SW:storage devices on all of the stack *Mar 1 00:04:22.537:%IMAGEMGR-6-AUTO_ADVISE_SW:members have been scanned, and it has *Mar 1 00:04:22.537:%IMAGEMGR-6-AUTO_ADVISE_SW:been determined that the stack can be *Mar 1 00:04:22.537:%IMAGEMGR-6-AUTO_ADVISE_SW:repaired by issuing the following *Mar 1 00:04:22.537:%IMAGEMGR-6-AUTO_ADVISE_SW:command(s):

*Mar 1 00:04:22.537:%IMAGEMGR-6-AUTO_ADVISE_SW:

*Mar 1 00:04:22.537:%IMAGEMGR-6-AUTO_ADVISE_SW: archive download-sw /force-reload /overwrite /dest 1 flash1:c3750e-universal-mz.122-35.SE2.tar

*Mar 1 00:04:22.537:%IMAGEMGR-6-AUTO_ADVISE_SW:

For information about using the archive download-swprivileged EXEC command, see the “Working with Software Images” section on page B-20.

Catalyst 3750-E and 3560-E Switch Software Configuration Guide

5-14

OL-9775-02

 

 

Page 134
Image 134
Cisco Systems 3750E manual Mar 1 000422.537%IMAGEMGR-6-AUTOADVISESW